Installation and operation instructions
Installation and operation instructions
HOBS
7
Gas flow to burners (gas burner capacity) is
regulated by means of knobs (Figure 2). The
knobs, in turn, are controlled by cocks.
Symbols “Max. flame” , “Min. flame” and
“Flame OFF”
are on the hob, close to cont-
rol knobs. Close to the symbol “Max. flame”
there is the “Ignition sparks” symbol which
means that the appliance is equipped with an
automated system of electrical ignition.
Attention! Any operating position of a
control knob shall be selected between
“Max. flame” and “Min. flame” . Bet-
ween these positions one can smoothly
adjust continuous and stable supply of
gas to gas burners of the hob. In no cir-
cumstances select an operating positi-
on between “Max. flame” and “Flame
OFF”
.
For a more convenient flame control ignite gas
prior to putting the dishware onto the grid.
Any model described herein is equipped with
electrically-ignited gas burners, but some mo-
dels have, in addition to that, a gas escape pre-
vention system (alternatively, it is called “gas
control”). Figure 3 presents a general view of a
disassembled gas burner. Its main components
as follows can be highlighted:
Fig. 2
1. Gas burner cap
2. Flame spreader
3. Igniter
4. Thermoelement of “gas control”.
Let us consider specifics of gas ignition in
both cases.
Fig. 3
GAS HOB CONTROL