19
Step 1) Setting the lamination temperature – the initially set temperature upon switching on
the equipment is 85°C. The setting may be changed by T+ button to increase the temperature
and T- to reduce the temperature on the main roller.
Step 2) Setting the lamination speed – the speed of the lamination is regulated by
potentiometer on the control panel, the control of the speed is independent of the FUNCTION
key; this display option shows the real speed of the lamination.
Step 3) Length counter (length of the foil used up) – To reset the length, it is necessary to hold
the FUNCTION key for approx. 5 sec. Menu for resetting the length appears on the display,
the value of the length may be reset by the T+ button.
Step 4) Sheet counter (the number of separated laminated sheets) – To reset this value, it is
necessary to hold the FUNCTION key for approx. 5s. Menu for resetting the number of sheets
appears on the display, the number of sheets may be reset by the T+ button.
Step 5) Activation or deactivation of the sensors – this menu may be accessed only from the
sheet number reset setting. Here, we press the FUNCTION key instead of the T+ button for
approx. 8 sec. The display will show the current sensor setting. This setting can be changed
by pressing the T+ button.
4.3 FUNCTION key (for older versions)
Using the
FUNCTION
key, we may change between five display options (see the
development chart).
Step 1) Lamination temperature setting – The initially set temperature upon switching on the
machine is 85°C, the setting may be changed by the T+ button to increase the temperature and
by the T- button to reduce the temperature on the main roller.
Step 2) Lamination speed setting – the speed of the lamination is regulated by the
potentiometer on the control panel, the speed control is independent of the FUNCTION key,
this display shows us the real lamination speed.
Step 3) Length counter (length of used up foil) – to reset the length, it is necessary to press the
FUNCTION key twice. Menu for resetting the length appears on the display, by the T+
button, we reset the length value. To control the state of the resetting, it is necessary to run the
entire FUNCTION key program again.
Step 4) Sheet counter (number of separated laminated sheets) – To reset the number of sheets,
it is necessary to press the FUNCTION key twice. Menu for resetting the number of sheets
appears, by pressing the T+ button, we reset the number of sheets. To control the state of
resetting, it is necessary to run the entire FUNCTION key program again.
Step 5) Activation or deactivation of the sensors – the display shows the current setting of the
sensors. This setting may be changed by pressing the T+ button.
Summary of Contents for Foliant 370T