30
5. Place the new FUSE into the same slot.
6. Install the FUSE DRAWER. (Refer to
Figure 7.1
.)
Accessory Fuse
When one or both ACCESSORY FUSES are blown,
the ACCESSORY POWER OUTLET and the
machine plugged into this outlet lose power.
WARNING
UNPLUG THE POWER CORD BEFORE OPENING
THE FUSE DRAWER.
7.2.2 To replace an
ACCESSORY FUSE:
1. Use a small screwdriver or similar tool to press in
and slightly rotate the FUSEHOLDER CAP
counterclockwise. (Refer to
Figure 7.1
.)
2. Inspect the FUSE; look for blackened glass,
melted wire or a disconnected wire between the
ends of the tube. If you find any of these
problems in the FUSE, it is blown and must be
replaced. If the first FUSE is fine, repeat steps 1
and 2 for the second FUSE.
3. Pull the blown FUSE from its slot.
WARNING
REPLACE ONLY WITH SAME TYPE AND RATING
OF FUSE. (REFER TO CHART BELOW.)
Selected Voltage
Line Fuse Value
100V…………………… 6.3A (250V time delay)
120V…………………… 6.3A (250V time delay)
220V…………………… 3.15A (250V time delay)
240V (or 230V)……….. 3.15A (250V time delay)
4. Place the new FUSE into the same slot.
5. Install the FUSEHOLDER into the same slot.
Refer to Fig. 7.1