TROUBLESHOOTING
TROUBLE
POSSIBLE CAUSE
REMEDY
Control panel lights are
not illuminated.
No power at the wall outlet.
No power to the machine inlet.
No power to the control panel.
Internal electrical failure
Check wall outlet.
Check power cord for frayed/broken
wires.
Press the black breaker reset button
located on the backside of the sealer,
see pg. 12 Fig. 17.
Call for service
Fold plate stop not
moving when “Fold
Setup” is pressed.
Fold plate is not plugged in.
Electrical or mechanical failure
Plug fold plate in.
Call for service.
Sealer does not turn on
when the form enters
the throat of the sealer
transport deck.
Sealer is not turned on
Sealer reset button has not
been pressed after a paper jam
Sealer breaker has popped
Photo eye is not detecting the
form
Check that the sealer is plugged in and
turned to the on position.
Press the “counter reset” button to reset
the sealer
Press the black breaker reset button
located on the backside of the sealer,
see pg. 12 Fig. 17.
Wipe sensor with dry cloth.
Call for service
Standard fold is
misfolding
Fold plate is not plugged in.
Wrong fold is selected
Fold plates are not inserted
correctly.
Piece of paper or other material
is stuck in the fold plate.
Plug fold plate in.
Check to make sure the correct fold is
selected from the “Standard fold menu”
A custom fold may need to be created
if the fold varies from the standard fold
setting, see pg 9 for custom fold setup.
Remove and reinstall fold plates. Be
sure they’re properly positioned.
Remove object from the fold plate.
10