Section 4 - Familiarization of Your New Motorhome
Foretravel Owners Manual
Page 4-11
Rev. 06-02
Press and hold the Extension Control Switch to the RETRACT position.
The red indicator light will stay on while pump is running.
When the retract sequence is completed the pump will shut off and the red
indicator light will go out. The RETRACT switch may be released.
The air seal will inflate when the room control key is switched OFF.
Repeat for slide-out on opposite side of coach.
Press Travel Mode button on HWH level pad.
CAUTION
THE SLIDE-OUT ROOM IS NOT DESIGNED TO BE USED IN A
PARTIALLY EXTENDED CONDITION. BE CERTAIN THAT EACH CY-
CLE IS COMPLETED AND THE RED INDICATOR LIGHT IS OFF BE-
FORE TURNING OFF KEYS.
R
EMOTE
S
TART
P
ANEL
The remote engine start panel is located in the engine compartment behind
the rear grill. The FILTER MINDER
air filter restriction indicator, a remote
START button, an oil pressure light, and an engine STOP button are included
on the panel as detailed below.
1. FILTER MINDER
Indicates restriction in air filter. As the filter becomes restricted a yellow band
will move up until it meets the red band at 25”.
Turbo charged engines must be working under full load to obtain the re-
stricted air flow condition. The FILTER MINDER shows this condition, even
after the engine is shut down.
Each air cleaner system has a certain amount of built in air restriction even
with new filter elements and should be noted when elements are new and the
engine is under a full load. Temporary conditions such as snow or inlet screen
clogging, can cause a high reading. The FILTER MINDER can be reset by
pushing the yellow tab at the bottom of the gauge. Service requirements are set
at 25" H
2
O for all coaches. This is the point where the life of the filter element
is expended and replacement is necessary. Additional dirt in the element will
cause a rapid rise in air flow restriction, black smoke, high fuel consumption,
and low power. Operation should not continue or engine damage can occur.