13
LIGHTING INSTRUCTIONS
Make 2~3 oz. of leak solution by mixing one part liquid dishwashing detergent and three parts water. Noted:
make sure control knob is “OFF”.
Apply several drops of solution where the cylinder attaches to regulator (see Figure 18), inspect the solution
at the connection looking for bubbles. If NO bubbles appear, the connection is secure. If bubbles appear, the
connection has the leak, disconnect the regulator, reconnect, perform another leak check. If you continue to
see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s supplier.
Apply several drops of solution where gas valve attaches to bellows (see Figure 19), where gas valve
attaches to hose (see Figure 20), and where inlet tube attaches to bellows (see Figure 21). If NO bubbles
appear, the connections are secure. If bubbles appear, the connection has the leak, disconnect,
reconnect,perform another leak check. If you continue to see bubbles after several attempts, the part is
defective and should replace the part.
1. Depress control knob slightly and turn to “OFF”.
2. Depress control knob and turn to “ON/MIN”.
3. Continue to depress the ignition button for 15 seconds.
4. If the burner does not light in 15 seconds, release the knob and it will pop back out. Wait 5 minutes before
attempting to light the burner again, repeat step1 to 3.
WARNING:
For your safety, read and follow the Lighting Instructions in this manual and in the Rating Plate on
the appliance. IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD OR
EXPLOSION HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
TO TURN OFF GAS
1. Depress control knob slightly and turn to “OFF”.
To perform a leak test:
gas valve-hose connection (Figure 20)
inlet tube-bellows connection (Figure 21)
Figure 22
1.
2.
3.
gas control knob
ignition button
LIGHTING INSTRUCTIONS
1. Depress control knob slightly and turn to “OFF”.
2. Depress control knob and turn to “ON/MIN”.
3. Continue to depress the ignition button for 15 seconds.
4. If the burner does not light in 15 seconds, release the
knob and it will pop back out. Wait 5 minutes before
attempting to light the burner again, repeat step1 to 3.
1. Depress control knob slightly and turn to “OFF”.
TO TURN OFF GAS
INSTRUCCIONES DE ENCENDIDO
PARA CERRAR EL GAS
1. Presione ligeramente la perilla de control del gas y gírela a la
posición “APG” (apagado).
2. Appuyer sur le bouton de commande et tourner à “ENC./MÍN.”
(encendido/mínimo).
3. Siga presionando el botón de encendido durante 15 segundos.
4. Si el quemador no se enciende en 15 segundos, suelte la perilla
y esta volverá a su posición hacia afuera. Espere 5 minutos antes
de intentar encender el quemador nuevamente, repita los pasos
1 al 3.
1. Presion ligeramente la perilla de control del gas y gírela a la
posición “APG” (apagado).
OFF (APG.)
MAX
(MÁX.)
1 AAA
1.5V
IGNITOR
( Encendedro )
ON/MIN
(ENC./MÍN.)