Low Battery Shut-Off <10V
●
If the battery voltage drops lower than 10V, then
the energiser will enter into a “pause mode” and
stop producing a high voltage pulse.
●
Then one of the green mode LEDs
(either Full or Half-Power) flashes, alternating
with the red LED.
This will help protect your battery’s life-span.
Running a 12V Lead-Acid battery lower than
10V will damage the cells.
Output Voltage / Battery Voltage
Chart (approx. voltage)
red
green
green
green
green
green
8000
6500
5000
3500
2000
<2000
100
80
60
40
20
<20
Fence Indicator
Approx Output
Voltage
Battery Indicator
Approx Battery
Charge
kV
%
Battery Life
This energiser gives you many options for
what rechargeable battery amp hour (Ah)
capacity to use. Refer to the below chart,
as an example, when selecting a lead-acid
or marine type rechargeable battery to
know how many days this battery will run
your energiser until you have to replace/
recharge.
These are approximate and are only valid
for healthy batteries. The older the battery,
and the more times it's been recharged,
the less capacity it will have.
Note:
If you want to extend the battery life, then swap batteries when only one green
battery-check LED is lit (during the battery test mode). This will prevent you from
over-discharging the battery and help extend the battery life.
Also, after replacing batteries immediately recharge the discharged battery to extend
its life and sustain its rated capacity.
Step 8: Test Battery Condition (continued)
Days of life with a given battery capacity
100Ah
170Ah
280Ah
Model
Full
Power
Half
Power
Full
Power
Half
Power
Full
Power
Half
Power
1 J
3 J
39
14
69
28
68
24
116
48
109
40
194
80
5 J
9
16
15
28
25
46
ENERGISER TEST continued. Page 13