background image

FORCE America ONE

TM

 Quick Start Manual 

Entering Calibration 

 

12

 

 

 

Hoist/Plow 

The Hoist/Plow menu allows you to configure settings related to the operation of the hoist and 
plow. 

 

Options 

The Options item allows you to configure which of the hydraulic functions can be 
activated using the unit.  The default value is Hoist & Plow. 

 

Option 

Description 

Hoist & Plow 

The system will contain switch functions and outputs for the 
hoist up, hoist down, plow up, plow down, plow left and plow 
right hydraulic functions. 

Hoist 

The system will contain switch functions and outputs for the 
hoist up, and hoist down hydraulic functions. 

Plow 

The system will contain switch functions and outputs for the 
plow up, plow down, plow left and plow right hydraulic 
functions. 

 

Plow Float 

The Plow Float menu item sets the operation of the Plow Down Float function.  When 
active the plow down float function will keep 12 V on the plow down output.  The plow 
down float function is deactivated by pressing the plow up switch.  The default value is 
Disabled. 

 

Option 

Description 

Disabled 

Plow float is not active. 

Delayed 

Plow float will activate when the plow down function is held for 
3 seconds. 

Enabled 

Plow float will activate when the plow down function is 
pressed. 

 

Max DC 

The Max DC submenu allows you to set the duty cycle that the switch related hydraulic 
functions will operate at during standard operation.  
 

Plow Up 

The Plow Up menu item adjusts the duty cycle that the plow up output will 
operate at during standard operation. The default value is 80%. 
 

Plow Left 

The Plow Left menu item adjusts the duty cycle that the plow left output will 
operate at during standard operation. The default value is 50%. 
 

 

 

 

 

Enter Access Code. 

 

Return to the Main menu. 

Summary of Contents for America ONE SSC5100ex

Page 1: ...FORCE America ONETM Quick Start Manual ...

Page 2: ......

Page 3: ...ng For advanced operation and calibration features related to the SSC5100ex Spreader Control please consult M0118 SSC5100ex Operation Manual or M0119 SSC5100ex Calibration Manual Table of Contents Welcome i Table of Contents i Hardware 1 FORCE America ONETM System Operation 2 Powering up the SSC5100ex 2 The Operation Screen 3 Remote Controls Operation 10 FORCE America ONETM System Calibration 11 E...

Page 4: ......

Page 5: ...unctions that they control change depending on what options are enabled See Switch Labels on page 4 The left side of the SSC5100ex has a single USB port which can be used to import and export calibration files or upgrade the firmware Figure 1 The SSC5100ex The remote controls provides the operator with three rotary adjustment knobs inputs for remote activation of blast and standby and control of h...

Page 6: ... consult M0018 SSC5100ex Operation Manual Powering up the SSC5100ex Upon applying 12V DC dashkey power to the SSC5100ex it will display the Screen Power Switch The Screen Power Switch The Screen Power Switch is a safety feature of the SSC5100ex it will prevent the system from running spreader related outputs until the Continue button is pressed When the Continue button is pressed it will display t...

Page 7: ...n 3 The Operation Screen The Operation Screen is the main screen of the SSC5100ex and provides controls for all of the system functions as well as access to the menus The operation screen is divided into three distinct parts Figure 4 SSC5100ex Operation Screen ...

Page 8: ...e same time will move the hoist up Pressing both the bottom switch and the interlock will move it down The Hoist Plow option in calibration must be set to Hoist or Hoist Plow Momentarily activates the Plow running it at max duty cycle until the switch is released The interlock switch is not required to run these functions Pressing the top switch will move the plow up and the bottom switch will mov...

Page 9: ...tus icon if Event Logging is set to PreCise System Status Messages will be displayed in the center of the Header Bar If two or more system status messages are active the messages will alternate between each other at a rate of one message every two seconds In Figure 6 above a Body Up condition has occurred showing the Body Up system status message in the header bar For more information on error con...

Page 10: ...appear when applying granular materials and adjusted using the blue knob The green row contains information about your primary material and its set rate This row is always visible and adjusted using the green knob The white prewet row contains information about your prewet material and its set rate The prewet row will only appear when applying granular materials and Prewet is enabled in Calibratio...

Page 11: ... control from standby Granular material will spread regardless of whether the vehicle is moving or not STEP 4 Press the On Standby knob to place the spreader control back in standby and stop the outputs To spread granular and prewet material in manual mode STEP 1 Press the top half of the switch labeled Prewet above the screen to enable prewet liquid application The switch s ON text will turn gree...

Page 12: ...Press the Back button to return to the operation screen STEP 11 Press the On Standby knob to remove the spreader control from standby Granular and prewet material will spread regardless of whether the vehicle is moving or not STEP 12 Press the On Standby knob to place the spreader control back in standby and stop the outputs ...

Page 13: ...on the Operator Interface The system will blast for its configured amount of time and return to normal operation The Blast feature works whether or not the system is in Standby or the vehicle is moving To deactivate Blast before it automatically shuts off STEP 1 While the system is Blasting press the Blue Blast Knob on the Operator Interface The Blast feature will shut off and return to its previo...

Page 14: ...er set rate Twist Right Increase the spinner set rate Pushbutton Blast granular material Cancel Blast Gray Prewet Knob Twist Left Decrease the prewet set rate Twist Right Increase the prewet set rate The prewet system can be turned on and off using the rocker switch located below the gray knob this rocker switch performs the same operation as the far right switch on the spreader control The joysti...

Page 15: ... it will appear You can insert a USB supervisor key instead of entering the access code to access the Calibration Menu To enter Calibration using Access Code 1 While the system is in Standby press the Menu button on the Operation Screen 2 Press the Calibration menu button The Access Code window will appear as shown in Figure 9 Figure 9 The Access Code Window 3 Enter the access code using the up an...

Page 16: ...The Plow Float menu item sets the operation of the Plow Down Float function When active the plow down float function will keep 12 V on the plow down output The plow down float function is deactivated by pressing the plow up switch The default value is Disabled Option Description Disabled Plow float is not active Delayed Plow float will activate when the plow down function is held for 3 seconds Ena...

Page 17: ...it Percentages submenu allows you to set the percentage of maximum range that the switch related hydraulic function will operate at when in limit mode Limit mode is active whenever more than one of the following functions is active Plow up plow left plow right hoist up hoist down or auger The values in this menu are only editable when the Limit Scheme is set to Custom Plow Up The Plow Up menu item...

Page 18: ...hat are not documented in this manual M0118 SSC5100ex Operation Manual or the M0119 SSC5100ex Calibration Manual please contact your local FORCE America Sales Representative for assistance For company and product information please contact FORCE America at Phone 1 888 99FORCE 1 888 993 6723 Website http www forceamerica com E mail info forceamerica com ...

Page 19: ......

Page 20: ...Document No M0125 C Released 08 09 2016 Copyright 2016 FORCE America Inc ...

Reviews: