Hoist/Plow Calibration
13
Plow Right
The Plow Right menu item adjusts the duty cycle that the plow right output will
operate at during standard operation. The default value is 50%.
Hoist Up
The Hoist Up menu item adjusts the duty cycle that the hoist up output will
operate at during standard operation. The default value is 65%.
Limit Scheme
The Limit Scheme menu item selects the limit scheme profile that is used to limit the
output duty cycle when multiple hydraulic functions are requested to run at the same
time. The default limit scheme is low.
Option
Description
High
High limit operation is designed to be used with a 14 GPM
pump
Low
Low limit operation is designed to be used with a 9 GPM
pump.
Custom
Custom limit operation will allow for setting of the various limit
percentages to obtain the desired operation if the High and
Low limit scheme do not provide the desired operation.
Limit Percentages
The Limit Percentages submenu allows you to set the percentage of maximum range that
the switch related hydraulic function will operate at when in limit mode. Limit mode is
active whenever more than one of the following functions is active: Plow up, plow left,
plow right, hoist up, hoist down or auger. The values in this menu are only editable when
the Limit Scheme is set to Custom.
Plow Up
The Plow Up menu item adjusts the limit percentage for the plow up output. The
custom default value is 50%.
Plow Left
The Plow Left menu item adjusts the limit percentage for the plow left output. The
custom default value is 70%
Plow Right
The Plow Right menu item adjusts the limit percentage for the plow right output.
The custom default value is 70%
Hoist Up
The Hoist Up menu item adjusts the limit percentage for the hoist up output. The
custom default value is 50%
Hoist Down
The Hoist Down menu item adjusts the limit percentage for the hoist down
output. The custom default value is 50%
Auger
The Auger menu item adjusts the limit percentage for the auger output. When
the auger output is being limited the prewet output will be adjusted as well. The
custom default value is 62%