- 5 -
5.-
AUX
: auxiliary input. Input for signal source, for connecting through RCA connectors from audio sources.
6.-
LINE-PHANTOM 24 V-MIC:
input and 24 V phantom sensitivty switches. These switches have 3
positions:
LINE:
in this position, high level audio sources can be connected to inputs 1 to 4: preamplified
microphones, CD, tape, tuner, etc.
MIC:
in this position, low impedance 30 - 600 Ω dynamic microphones can be connected to inputs 1 to 4.
PHANTOM 24 V:
in this position, electret condenser microphones that require 24 V phantom power
can be connected to inputs 1 to 4.
Use this switch with volume at its minimum to avoid noise.
7.-
INPUT 1 to 4:
microphone/line inputs that use a combined XLR and 6.3 mm jack connector, accepting
balanced and unbalanced 30 - 600 Ω microphone signals and balanced electret condenser microphones
that need 24 V phantom power, present in pins 2 and 3 of the XLR connector. High level balanced or
unbalanced line signals from mixers, CD, tape, tuner, etc. are accepted.
Select the appropriate position with the switch, taking care to move the volume controls to their
minimum to avoid noises.
The microphone 1 input has the priority function, cancelling all other inputs to give preference to paging
and emergencies, etc. The amplifier is provided with priority cancelled. To activate this function, you
must turn the MUTE/SEN control on the back panel clockwise, to its maximum (maximum priority).
PRECAUTION
: when you connect or disconnect an unbalanced microphone, the switch must be in the
MIC position. If the switch is in the PHANTOM 24 V position it could damage the microphones. When
you use microphones that do not require phantom power, make sure that the switch is in the MIC
position, as the voltage present in pins 2 and 3 of the XLR connector could damage the microphones.
If in doubt, contact your supplier or the FONESTAR technical service..
8.-
MUTE/SEN:
control for activating/deactivating the priority in inputs INPUT 1 and TEL. Turn the control
clockwise to maximum and the rest of the controls will weaken automatically when a signal is detected
in inputs INPUT 1 or TEL. Turn it anti-clockwiseand the priority function will move to its minimum.
Note:
the amplifier is supplied with priority deactivated. To activate this function you must turn the
MUTE/SEN control clockwise, to maximum (maximum priority).
9.-
GND. Earth:
earth screw, to use if the mains does not have one installed.
10.-
AC socket:
for connecting the AC mains cable.
11.-
DC Power Input:
24 V DC power supply. For the amplifier to operate with 24 V DC power, batteries,
emergency power system, etc. Make the connection with 2.5 mm2 section cable to the - negative and
+ positive terminals.
Note
: when the amplifier is used with 24 V DC the power is reduced by approximately 20%.
12.-
OUTPUT:
loudspeaker output. For connecting the loudspeakers in low impedance 4 Ω and in high
impedance lines of 100/70/25 V. Connect the speaker line between the COM terminal and the
impedance or line in the desired V.