- 5 -

5.-

AUX

: auxiliary input. Input for signal source, for connecting through RCA connectors from audio sources.

6.-

LINE-PHANTOM  24  V-MIC:

input  and  24  V  phantom  sensitivty  switches.  These  switches  have  3

positions:

LINE:

in  this  position,  high  level  audio  sources  can  be  connected  to  inputs  1  to  4:  preamplified

microphones, CD, tape, tuner, etc.

MIC:

in this position, low impedance 30 - 600 Ω dynamic microphones can be connected to inputs 1 to 4.

PHANTOM 24 V: 

in this position, electret condenser microphones that require 24 V phantom power

can be connected to inputs 1 to 4.

Use this switch with volume at its minimum to avoid noise.

7.-

INPUT 1 to 4: 

microphone/line inputs that use a combined XLR and 6.3 mm jack connector, accepting

balanced and unbalanced 30 - 600 Ω microphone signals and balanced electret condenser microphones
that need 24 V phantom power, present in pins 2 and 3 of the XLR connector. High level balanced or
unbalanced line signals from mixers, CD, tape, tuner, etc. are accepted.

Select  the  appropriate  position  with  the  switch,  taking  care  to  move  the  volume  controls  to  their
minimum to avoid noises.

The microphone 1 input has the priority function, cancelling all other inputs to give preference to paging
and emergencies, etc. The amplifier is provided with priority cancelled. To activate this function, you
must turn the MUTE/SEN control on the back panel clockwise, to its maximum (maximum priority).

PRECAUTION

: when you connect or disconnect an unbalanced microphone, the switch must be in the

MIC position. If the switch is in the PHANTOM 24 V position it could damage the microphones. When
you use microphones that do not require phantom power, make sure that the switch is in the MIC
position, as the voltage present in pins 2 and 3 of the XLR connector could damage the microphones.
If in doubt, contact your supplier or the FONESTAR technical service..

8.-

MUTE/SEN:

control for activating/deactivating the priority in inputs INPUT 1 and TEL. Turn the control

clockwise to maximum and the rest of the controls will weaken automatically when a signal is detected
in inputs INPUT 1 or TEL. Turn it anti-clockwiseand the priority function will move to its minimum.

Note:

the amplifier is supplied with priority deactivated. To activate this function you must turn the

MUTE/SEN control clockwise, to maximum (maximum priority).

9.-

GND. Earth: 

earth screw, to use if the mains does not have one installed.

10.-

AC socket: 

for connecting the AC mains cable.

11.-

DC Power Input:  

24 V DC power supply. For the amplifier to operate with 24 V DC power, batteries,

emergency power system, etc. Make the connection with 2.5 mm2 section cable to the - negative and
+ positive terminals.

Note

: when the amplifier is used with 24 V DC the power is reduced by approximately 20%.

12.-

OUTPUT:

loudspeaker output. For connecting the loudspeakers in low impedance 4 Ω and in high

impedance  lines  of  100/70/25  V.  Connect  the  speaker  line  between  the  COM  terminal  and  the
impedance or line in the desired V.

EN

MA-125Z_MANUAL_(EN)_20170824_Maquetación 1  24/8/17  10:23  Página 5

Summary of Contents for MA-125Z

Page 1: ...MA 125Z AMPLIFIER WITH ZONE SELECTOR INSTRUCTION MANUAL...

Page 2: ...to allow ventilation Avoid direct sunlight heat sources and excessive dust Do not place the machine near magnetic elds or static electricity Do not use surfaces which vibrate or receive impact Do not...

Page 3: ...ne shows that when the product is disposed of it must be done properly placing it in a special selective electronic and electrical equipment container or through a dealer when purchasing a similar pro...

Page 4: ...istorted signal that could damage the loudspeakers or the ampli er 6 ZONE SELECTOR ZONE 1 to ZONE 4 there are 4 individual zone controls and a general control The loudspeaker line from one zone can be...

Page 5: ...imum maximum priority PRECAUTION when you connect or disconnect an unbalanced microphone the switch must be in the MIC position If the switch is in the PHANTOM 24 V position it could damage the microp...

Page 6: ...loudspeaker as a monitor A 1 W internal ampli er is available It only monitors the AUX IN input controlled by the AUX volume and its level is adjustable using the LEVEL MOH control on the back panel 1...

Page 7: ...ance output you must connect the speakers in a series parallel circuit so that the loudspeaker charge impedance is the same as the ampli er output impedance and the power supplied by the ampli er does...

Page 8: ...EN 8 BLOCK DIAGRAM...

Page 9: ...screw terminals 600 100 mV OUTPUTS 1 line out 2 x RCA 47 000 1 V 1 pre out RCA 600 1 V 1 monitor screw terminals 600 775 mV and 1 W 8 aux input CONTROLS Tone Bass 10 dB Treble 10 dB Volume inputs 1 t...

Page 10: ...mponents by unauthorized persons and in general any use that is unrelated to the nature and purpose of the product If any service is needed during the warranty period because of lack of conformity ple...

Page 11: ...11 EN...

Page 12: ...www fonestar com...

Reviews: