60 se
c
HEATIN
G
DELA
Y
BACK
11:2
4
THERMOSTAT
HEATIN
G
WATE
R
DO
MESTIC
HO
T WATER
DIFFE
RE
NTIA
L
RE
GULATI
ON
TY
PE
CU
RV
E
PROPORTIONAL
FACT
OR
HEATIN
G
DELA
Y
11:2
4
BA
CK
60 se
c
HEATIN
G
DELA
Y
HEA
TING DELA
Y
: with this parameter you delay the boiler
ignition to allow the zone valves to open.
At the end of a heating
request, it is the zone valve that closes late to ensure correct post-circulation to the boiler pump.
The installer is asked to check the opening time in the characte
-
ristics of the valve and to set the Heating delay to the same value [do not set below 30 seconds].
Summary of Contents for SPOT SMART THERMOSTAT
Page 7: ...How to select and set the time How to select and set the temperature...
Page 35: ......
Page 38: ......