: with this parameter you delay the boiler 

ignition to allow the zone valves to open. 

At the end of a heating 

request, it is the zone valve that closes late to ensure correct  post-circulation to the boiler pump.

The installer is asked to check the opening time in the characte

-

ristics of the valve and to set the Heating delay to the same  value [do not set below 30 seconds].

Summary of Contents for SPOT SMART THERMOSTAT

Page 1: ...SPOT SMART THERMOSTAT INSTALLATION USE OFF EN Translation of the original instructions in Italian IST 03 C 1349 01...

Page 2: ...rmitted All installation or maintenance operations must be carried out by qualified personnel The manufacturer cannot be held responsible for any damage to persons animals and or property caused by im...

Page 3: ...e under supervision or have been instructed in the use of the ap pliance Children may not play with the appliance and or clean the appliance unless they have been properly instructed beforehand WARNIN...

Page 4: ...3 Battery duration approx 2 years Fastening screws and plugs on bracket with integrated level GATEWAY RADIO RELAY CHARACTERISTICS Power supply 230Vac 10 15 Frequency 50 60Hz Relay dry contact gateway...

Page 5: ...on off 4 heating request in progress 4 DHW request in progress 5 technical support enabling 5 battery 100 5 battery 75 5 battery 50 KEY 5 battery 25 5 low battery 6 progr thermostat in manual mode 6...

Page 6: ...n gestures turn press press for three seconds wait for five seconds Set temperature 21 0 Set programmable thermostat function copy whole day paste whole day exit day of the week click to change day of...

Page 7: ...How to select and set the time How to select and set the temperature...

Page 8: ...perating mode Programmable thermostat settings It is possible to set 4 time slots per each day with free temperature for each time slot Setting of the tempera ture in the times outside the time slots...

Page 9: ...CK Date and time setting Language set up Boiler thermore gulation setting Domestic hot water settings Area relay delay setting Display of Mac address Bluetooth signal quality Connection status Battery...

Page 10: ...Operating mode MODE BACK WINTER OFF SUMMER WINTER OFF SUMMER WINTER OFF SUMMER WINTER OFF SUMMER OFF...

Page 11: ...d to produce both hot water for heating and domestic hot water SUMMER the boiler is enabled to produce domestic hot water only Heating is disabled OFF each boiler operation request is disabled Antifre...

Page 12: ...CH temperature setting HEATING WATER MAX MIN 70 C 30 C 11 24 THERMOSTAT 11 24 BACK BACK HEATING WATER MAX MIN 70 C 30 C HEATING WATER MAX MIN 70 C 30 C HEATING WATER...

Page 13: ...room temp external temp room external MAX is the maximum temperature of the heating water that the boiler will provide in modulating operation regulation type room temp external temp room external MAX...

Page 14: ...DHW temperature setting BACK HEATING WATER DOMESTIC HOT WATER DOMESTIC HOT WATER 49 C 49 C DOMESTIC HOT WATER 11 24 THERMOSTAT...

Page 15: ...DOMESTIC HOT WATER the boiler will produce domestic hot water at the temperature set with this parameter...

Page 16: ...FERENTIAL ON OFF 0 1 0 CORR 0 0 5 0 11 24 THERMOSTAT HEATING WATER DOMESTIC HOT WATER DIFFERENTIAL DIFFERENTIAL ON value to be subtracted from the ambient set point that determines a heating request e...

Page 17: ...under which an antifre eze request is triggered regardless of the operating mode CORR ambient probe correction Value to add subtract to offset any error DIFFERENTIAL OFF value to be added to the ambie...

Page 18: ...ION TYPE ROOM TEMP EXTERNAL TEMP ROOM EXTERNAL ON OFF ROOM the temperature of the hot water for heating varies within MAX MIN values depending on the ambient tem perature This guarantees lower gas con...

Page 19: ...AL ON OFF BACK ROOM EXTERNAL the temperature of the hot water for hea ting varies within MAX MIN values depending on the external temperature and the ambient temperature EXTERNAL the temperature of th...

Page 20: ...g the regulation curve of hot water for heating to be made by the installer 11 24 THERMOSTAT DIFFERENTIAL REGULATION TYPE CURVE PROPORTIONAL FACTOR 11 24 BACK HEATING WATER DOMESTIC HOT WATER HEATING...

Page 21: ...3 The higher the value the greater the influence of the external temperature Values between 0 1 and 0 9 are values for floor systems Values between 1 and 3 are values for radiator systems Usually it...

Page 22: ...Proportional factor setting by the installer HEATING WATER DOMESTIC HOT WATER DIFFERENTIAL REGULATION TYPE CURVE PROPORTIONAL FACTOR HEATING DELAY 11 24 BACK 11 24 THERMOSTAT...

Page 23: ...PORTIONAL FACTOR this parameter affects the relation between external ambient temperature and heating water tem perature The range goes from 0 to 20 The higher the value the greater the influence of t...

Page 24: ...Heating delay setting by the installer 11 24 THERMOSTAT HEATING WATER DOMESTIC HOT WATER DIFFERENTIAL REGULATION TYPE CURVE PROPORTIONAL FACTOR HEATING DELAY 11 24 BACK...

Page 25: ...allow the zone valves to open At the end of a heating request it is the zone valve that closes late to ensure correct post circulation to the boiler pump The installer is asked to check the opening ti...

Page 26: ...ough the Webapp accessible from the Fondital website Technical support enabling From the settings page the user can enable or disable the remote control of the boiler and heating system by the Fondita...

Page 27: ...on for the first time re member to set the correct date and time WARNING the batteries can be replaced only by the user The manufactu rer cannot be held responsible for any damage to persons animals a...

Page 28: ...GATEWAY INSTRUCTIONS Gateway description Front Rst button reset programming BLE LED bluetooth blue WiFi LED blue not used Cloud LED blue Power LED green...

Page 29: ...US connector to be connected to the boiler Non polarised connection red live power supply 90 230 Vac 50 60 Hz black neutral power supply 90 230 Vac 50 60 Hz yellow green dry contact for zone valve ena...

Page 30: ...pply of the gateway so that it is in parallel with the boiler power sup ply downstream the same bipolar switch IT IS IMPORTANT THAT GATEWAY AND BOILER TURN ON AT THE SAME TIME Connect the dry open con...

Page 31: ...y Gateway status Cloud LED it signals the connection to the home Wifi network and to the Spot cloud Off it means that the Gateway is not connected to any WiFi network or no account has been connected...

Page 32: ...Step 2 Press and hold the Rst button until you see the BLE LED switching from 5 fast blinks per se cond to one blink per second Press and hold on the Spot thermostat from the main page for three secon...

Page 33: ...MYSPOT app from Google play store or Apple app store Open the App first create your account by following the App s instruc tions and then register the gateway to your home Wi Fi network Step 1 Step 2...

Page 34: ...hen select Jotto_Config_AP choose the WiFi network to which you want to connect the Gateway and type the correct password After connecting to the cloud the message indicating the presence of a new Spo...

Page 35: ......

Page 36: ...ls of the WiFi network you want to connect to and be sure that this network has an internet connection Step 1 Step 2 5 times Power up the Gateway wait for a couple of mi nutes Press the Rst button 5 t...

Page 37: ...then change on access point detail Then select Jotto_Con fig_AP choose the WiFi network to which you want to connect the Gateway and type the correct password After connecting to the cloud the app wi...

Page 38: ......

Page 39: ...the Rst button until you see the BLE LED switching from 5 fast blinks per se cond to one blink per second Click on the Rst button the Cloud LED will blink once per second it is possible to pair a WiFi...

Page 40: ...he third Spot thermostat follow steps 3 and 4 defined in the previous chapter Modify the Gateway Wi Fi network Press the Rst button again the Cloud LED will blink fast three times every second you are...

Page 41: ...Connect the relay as shown in the figure below Neutral output Phase 220VAC Neutral Connect to 230Vac zone solenoid valve Fondital zone kit Maximum current 10A at 230Vac The relay is modified according...

Page 42: ...3 Go to WiFi and select the net work Spot_RL_xxxx exit and open the browser and type the address 192 168 4 1 The following relay page will open click on Configure wifi The page shows the available WiF...

Page 43: ...e lay will stop blinking and will become steady if this is not the case repeat the procedure from the beginning Now the relay is ready to be paired with the Ga teway When you reach points 4 and 6 of t...

Page 44: ...boiler operating mode WINTER SUMMER OFF and adjust the domestic hot water temperature Each thermostat displays the current boiler status heating or domestic hot water request if the boiler burner is...

Page 45: ...RELE WIFI 230Vac V2 230Vac 230Vac 230Vac V1 V3 N L 230Vac 50Hz GATEWAY BUS 230Vac ROUTER RELE WIFI BOILER...

Page 46: ...2 TSM2 VM2 PR2 SEXT 230Vac GATEWAY BUS N L 230Vac 50Hz POWER POWER 230Vac ROUTER RELE WIFI BOILER ZONE 1 THERMOSTAT Z1 ZONE 2 ZONE 2 board THERMOSTAT Z2 ZONE 3 ZONE 3 board THERMOSTAT Z3 ZONE 1 RELAY...

Page 47: ...3 RELAY THERMOSTAT ZONE 3 BOARD BOILER ZONE1 AND ZONE3 THERMOSTATS it is mandatory to set the curves 0 BOILER Set P60 2 no of present zones Set P61 0 Set P10 high temperature curve Set zone 1 tempera...

Page 48: ...39 0365 878 31 Fax 39 0365 878 304 e mail info fondital it www fondital com The manufacturer reserves the right to modify his her products as deemed necessary without altering the basic characteristi...

Reviews: