BOILER STATUS

MALFUNCTION

PROBABLE CAUSE

SOLUTION

The boiler has shut down, the red 
light no. 1 is on.

Burner does not ignite.
Reset by pressing no. 16 button

Gas supply failure

Check gas network pressure
Check gas network safety valves to 
be open

Gas valve is disconnected

Reconnect gas valve

Gas valve is faulty

Replace it

PCB is faulty

Replace it

Burner does not ignites, there is no 
spark.
Reset by pressing no. 16 button.

Spark electrode is faulty

Replace the electrode

Flame detection PCB is faulty

Replace PCB

Burner ignites for  a few seconds and 
turns off.
Reset by pressing no. 16 button.

PCB does not detect flame: inverted 

phase and neutral

Verify correct neutral and phase  
connections

Flame detection electrode wire is 
disconnected or faulty

Connect flame detection electrode 

wire or replace it

Flame detection electrode is faulty

Replace electrode

Flame detection PCB does not detect 

flame: it is faulty

Replace flame detection PCB

P ACC Ignition value set point 
is too low

Adjust P ACC ignition value set point

Min heat input in not set correctly

Check burner adjustment

The boiler has shut down and 
red light no. 2 is on.
Reset by pressing no. 18 button.

Safety thermostat has shut the boiler 
down

Water is not flowing in the CH system: 

pipes are clogged, thermostatic 
valves are closed, intercepting valves 
in the system are closed

Check CH system

Pump is blocked or faulty

Check the pump

Plate heat exchanger is clogged

Check the plate heat exchanger

The boiler has shut down and red 

light no. 4 is flashing.

Restore correct water pressure

Insufficient water pressure

Possible water leaks

Check system for leaks

Pressure switch is disconnected

Reconnect it

Water pressure switch is faulty

Replace it

The boiler has shut down, red light  

no. 5 is  flashing.Boiler will 

automatically resume operation as 
soon as the problem is solved

Flow probe is faulty

Flow probe is disconnected

Reconnect it

Flow probe is faulty

Replace it

The boiler has shut down and red 

light no. 6 is flashing.

Boiler will automatically resume 
operation as soon as the problem is 
solved

Boiler communication to and from 
remote control is faulty

Connecting wire is faulty

Check connecting wire

The boiler has shut down, red light  

no. 7 is  flashing.

Boiler will automatically resume 
operation as soon as the problem is 
solved

Water tank is faulty

Water tank probe is disconnected

Reconnect it

Water tank probe is faulty

Replace it

The boiler has shut down, red light  

no. 8 is  flashing.

Boiler will automatically resume 
operation as soon as the problem is 
solved

Plate heat exchanger probe is faulty

Plate heat exchanger probe is discon-
nected

Reconnect it

Plate heat exchanger probe is faulty

Replace it

The boiler has shut down, red light  

no. 9 is  flashing (BTN model only).

Reset by pressing no. 19 button.

Flue gas thermostat is not consenting 
to boiler operation

Flue gas thermostat is faulty

Check flue gas thermostat operation: 

replace when faulty

Air inlet or flue gas discharge flow is 

not adequate

Check air inlet/flue gas discharge 

ducts: clean or replace as necessary

5. TROUBLESHOOTING

22

Summary of Contents for BALI B BTFSE 24

Page 1: ...IST 03 C 192 01 INSTALLATION USE AND MAINTENANCE BALI B BTNE 25 BTNE 32 BTNE 42 BTFSE 24 BTFSE 32 BTFSE 36 GB...

Page 2: ...Dear Customer Thank you for choosing and buying one of our boilers Please read these instructions carefully in order to install operate and maintain this equipment properly 1...

Page 3: ...ment sites Keep the packaging out of the reach of children as by its nature it may represent a hazard In the event of failure and or faulty functioning switch off the boiler Do not attempt to repair i...

Page 4: ...of temperature probes page 9 1 3 Maintenance page 9 1 4 Information for the user page 9 2 Technical characteristics and dimensions page 10 2 1 Technical characteristics page 10 2 2 Dimensions page 10...

Page 5: ...operates in CH and instantaneous DHW supply mode only As soon as the probe is replaced the boiler will resume operation 8 Indication light red when the light is on and fixed it indicates that the temp...

Page 6: ...liters per minute relies upon the boiler thermal output and water main supply temperature according to the fol lowing formula l DHW in liters per minute K T K represents 344 for BTFS 24 model 459 for...

Page 7: ...t when the boiler is equipped with an external temperature probe the user sets a fictitious room temperature va lue via knob 13 please see SLIDING TEMPERATURE OPERA TION section Knob 13 is used to adj...

Page 8: ...of the week current time ON and OFF pro grams please see below sections B and C B Setting the day of the week and current time Position selector 2 to RUN and press h and m buttons at the same time unt...

Page 9: ...will be displayed fixed and symbol will be displayed indicator 4 now the chan nel will be permanently active Rapidly set selector 1 to position O without stopping in position AUTO press once or twice...

Page 10: ...usehold products Do not use water As provided by law the boiler is to be serviced once a year Correct maintenance ensures boiler to function efficiently environmentally friendly preventing any danger...

Page 11: ...aracteristics High output cast iron heat exchanger Stainless steel plate DHW heat exchanger Stainless steel horizontal stratification 60 l water tank with sacrificial magnesium anode Glass wool alumin...

Page 12: ...inlet C DHW flow F Cold water inlet M CH flow R CH return G Gas inlet C DHW flow F Cold water inlet M CH flow R CH return M1 Low temperature zone flow M2 Low temperature zone return D Flue gas outlet...

Page 13: ...CAST HEAT EXCHANGER BURNER Plate heat exchanger probe Zone 1 high temperature Thermostatic valve DHW Cold water inlet Water tank probe Water tank VM 2 way Cold water inlet Zone 1 high temperature Zon...

Page 14: ...16 4 Water tank capacity l 60 60 60 60 60 60 DHW supply T 30K EN 625 l 10 220 242 280 215 245 253 prEN 13203 efficiency rating Min DHW flow rate l min 3 3 3 3 3 3 Min DHW pressure bar 1 1 1 1 1 1 Max...

Page 15: ...manual Four legs with threads 3 2 2 Choosing where to install the boiler When choosing where to install the boiler follow the instructions below indications in paragraph 3 2 5 Air flue gas system conf...

Page 16: ...lination toward the ground of at least 5 The terminal is to ensure efficient constant evacuation of flue gas in any weather condition The flue gas terminal is to stand at least 0 5 m above any adjacen...

Page 17: ...0 mm diameter split pipes Roof mounted flue gas terminal Allowable configuration for max length of split pipes 2 flanged stub pipes 1 meter long air intake pipe 30 meter long flue gas pipe 1 air intak...

Page 18: ...damage or injury cau sed by failure to properly earth the power main Gas lines DHW and CH pipes are not suitable for earthing purpo ses 3 2 9 Hydraulic connections Before connecting the boiler it is a...

Page 19: ...through water mains inlet tap on the boiler as necessary Water pressure adjustment must be performed when the system is cold The thermo manometer gauge on the boiler allows for che cking the pressure...

Page 20: ...er P3 boiler operating mode selector P2 DHW temperature adjusting potentiometer P1 CH temperature adjusting potentiometer IG two poled main power switch BC flame detection pcb VG gas valve E RIV flame...

Page 21: ...NECTION M1 M24 AVAILABLE CONNECTORS X1 X8 AVAILABLE CONNECTORS CT PHONE CONNECTION DEVICE OPTIONAL EQUIPMENT FUSE SP 2 AF 250 Vac FUSE FUSE SZ 2 5 AF 250 Vac FUSE P4 HIGH TEMPERATURE CH CURVES ADJUSTI...

Page 22: ...ted by qualified personnel In order to verify nozzle and gas inlet pressure connect a mano meter to checks on the gas valve Boilers are factory set according to gas type requested upon order Any later...

Page 23: ...the plate heat exchanger The boiler has shut down and red light no 4 is flashing Restore correct water pressure Insufficient water pressure Possible water leaks Check system for leaks Pressure switch...

Page 24: ...has not sufficient pressu re or flow rate Check DHW system Check flow meter filter Flow meter sensor is faulty or discon nected Replace or reconnect it Flow meter is blocked Replace it Burner does not...

Page 25: ...24...

Page 26: ...25...

Page 27: ...26...

Page 28: ...ax 39 0365 878 576 e mail fondital fondital it www fondital it The MANUFACTURER reserves the right to implement any necessary and or useful variation to products without modifying fundamental characte...

Reviews: