2. TECHNICAL CHARACTERISTICS AND DIMENSIONS

2.1 Technical characteristics

The boiler is equipped with a high output cast iron heat exchanger 
and atmospheric gas burners. 

All versions are equipped with electronic ignition, ionization flame 

detection  device, AQUA  PREMIUM  system  for  DHW  supply  em-

ploying a 60 ltrs stainless steel stratification water tank and a plate 

secondary heat exchanger.

The following versions are available:

BTN E 25: open chamber, natural draught boiler with 25.1 kW heat 
output;
BTN E 32: open chamber, natural draught boiler with 31.4 kW heat 
output;
BTN E 42: open chamber, natural draught boiler with 42.5 kW heat 
output.

BTFS  E  24:  sealed  chamber,  forced  draught  boiler  with  24.0  kW 
heat output;
BTFS  E  32:  sealed  chamber,  forced  draught  boiler  with  32.0  kW 
heat output;
BTFS  E  36:  sealed  chamber,  forced  draught  boiler  with  36.5  kW 
heat output.

All models are available in V version, equipped with collector, mixing 
valve and two additional pumps for management of one high tem-
perature zone and one low temperature zone.

In addition, the boiler is manufactured in accordance to laws and 
standards in force in the country named on the boiler technical 
data plate.
Installation in a different country from the one mentioned might 
endanger people, animals and cause damage to property.   

The main technical characteristics of the boiler are listed below:

Manufacture characteristics

- High-output cast iron heat exchanger
- Stainless steel plate DHW heat exchanger

- Stainless steel horizontal stratification 60 l water tank with 

  sacrificial magnesium anode

- Glass wool, aluminium layered, high thickness (50mm) insulation

- Plastic layered, metal sheet casing
- Gas valve 
- Motorized deviating valve
- Three-speed CH circulation pump 
- Single-speed DHW circulation pump 
- 12 lt. CH expansion vessel (18 lt. for BTN E 42 model)
- 5 lt. DHW expansion vessel
- CH water, water tank and plate heat exchanger temperature 
  probes
- Adjustable by-pass
- CH system air purging device

- DHW priority flow switch

- Safety limit thermostat (110°C)
- Air pressure switch (BTFS model)
- Flue gas thermostat (BTN)

- DHW filter

- CH system loading tap
- CH system unloading tap

- Insufficient water pressure safety switch

- Electronics ready to host an additional pcb for management 
  of three different CH zones (optional kit).

User interface

- Selector managing the following functions: PROGRAMMER, 
  COMFORT TEMPERATURE, REDUCED TEMPERATURE,
   ANTI-FROST,SUMMER
- CH water temperature adjusting knob 
- DHW water temperature adjusting knob 
- Power switch with light
- Led thermometer
- Pressure gauge
- Control panel with lights indicating: 

  • Power supply

  • CH water supply

  • Communication to remote control error

  • Flame detecting device shutdown

  • Overheating shutdown

  • Low water pressure shutdown

  • Temperature probe malfunction shutdown

  • Air inlet/flue gas system malfunction shutdown. 

2.2. Dimensions

pic. 5A

Model BTN E

G: Gas inlet
C: DHW flow
F: Cold water inlet
M: CH flow
R: CH return
D: Flue gas outlet
(130 mm for BTN 25,
150 mm for BTN 32 and BTN 42)

Summary of Contents for BALI B BTFSE 24

Page 1: ...IST 03 C 192 01 INSTALLATION USE AND MAINTENANCE BALI B BTNE 25 BTNE 32 BTNE 42 BTFSE 24 BTFSE 32 BTFSE 36 GB...

Page 2: ...Dear Customer Thank you for choosing and buying one of our boilers Please read these instructions carefully in order to install operate and maintain this equipment properly 1...

Page 3: ...ment sites Keep the packaging out of the reach of children as by its nature it may represent a hazard In the event of failure and or faulty functioning switch off the boiler Do not attempt to repair i...

Page 4: ...of temperature probes page 9 1 3 Maintenance page 9 1 4 Information for the user page 9 2 Technical characteristics and dimensions page 10 2 1 Technical characteristics page 10 2 2 Dimensions page 10...

Page 5: ...operates in CH and instantaneous DHW supply mode only As soon as the probe is replaced the boiler will resume operation 8 Indication light red when the light is on and fixed it indicates that the temp...

Page 6: ...liters per minute relies upon the boiler thermal output and water main supply temperature according to the fol lowing formula l DHW in liters per minute K T K represents 344 for BTFS 24 model 459 for...

Page 7: ...t when the boiler is equipped with an external temperature probe the user sets a fictitious room temperature va lue via knob 13 please see SLIDING TEMPERATURE OPERA TION section Knob 13 is used to adj...

Page 8: ...of the week current time ON and OFF pro grams please see below sections B and C B Setting the day of the week and current time Position selector 2 to RUN and press h and m buttons at the same time unt...

Page 9: ...will be displayed fixed and symbol will be displayed indicator 4 now the chan nel will be permanently active Rapidly set selector 1 to position O without stopping in position AUTO press once or twice...

Page 10: ...usehold products Do not use water As provided by law the boiler is to be serviced once a year Correct maintenance ensures boiler to function efficiently environmentally friendly preventing any danger...

Page 11: ...aracteristics High output cast iron heat exchanger Stainless steel plate DHW heat exchanger Stainless steel horizontal stratification 60 l water tank with sacrificial magnesium anode Glass wool alumin...

Page 12: ...inlet C DHW flow F Cold water inlet M CH flow R CH return G Gas inlet C DHW flow F Cold water inlet M CH flow R CH return M1 Low temperature zone flow M2 Low temperature zone return D Flue gas outlet...

Page 13: ...CAST HEAT EXCHANGER BURNER Plate heat exchanger probe Zone 1 high temperature Thermostatic valve DHW Cold water inlet Water tank probe Water tank VM 2 way Cold water inlet Zone 1 high temperature Zon...

Page 14: ...16 4 Water tank capacity l 60 60 60 60 60 60 DHW supply T 30K EN 625 l 10 220 242 280 215 245 253 prEN 13203 efficiency rating Min DHW flow rate l min 3 3 3 3 3 3 Min DHW pressure bar 1 1 1 1 1 1 Max...

Page 15: ...manual Four legs with threads 3 2 2 Choosing where to install the boiler When choosing where to install the boiler follow the instructions below indications in paragraph 3 2 5 Air flue gas system conf...

Page 16: ...lination toward the ground of at least 5 The terminal is to ensure efficient constant evacuation of flue gas in any weather condition The flue gas terminal is to stand at least 0 5 m above any adjacen...

Page 17: ...0 mm diameter split pipes Roof mounted flue gas terminal Allowable configuration for max length of split pipes 2 flanged stub pipes 1 meter long air intake pipe 30 meter long flue gas pipe 1 air intak...

Page 18: ...damage or injury cau sed by failure to properly earth the power main Gas lines DHW and CH pipes are not suitable for earthing purpo ses 3 2 9 Hydraulic connections Before connecting the boiler it is a...

Page 19: ...through water mains inlet tap on the boiler as necessary Water pressure adjustment must be performed when the system is cold The thermo manometer gauge on the boiler allows for che cking the pressure...

Page 20: ...er P3 boiler operating mode selector P2 DHW temperature adjusting potentiometer P1 CH temperature adjusting potentiometer IG two poled main power switch BC flame detection pcb VG gas valve E RIV flame...

Page 21: ...NECTION M1 M24 AVAILABLE CONNECTORS X1 X8 AVAILABLE CONNECTORS CT PHONE CONNECTION DEVICE OPTIONAL EQUIPMENT FUSE SP 2 AF 250 Vac FUSE FUSE SZ 2 5 AF 250 Vac FUSE P4 HIGH TEMPERATURE CH CURVES ADJUSTI...

Page 22: ...ted by qualified personnel In order to verify nozzle and gas inlet pressure connect a mano meter to checks on the gas valve Boilers are factory set according to gas type requested upon order Any later...

Page 23: ...the plate heat exchanger The boiler has shut down and red light no 4 is flashing Restore correct water pressure Insufficient water pressure Possible water leaks Check system for leaks Pressure switch...

Page 24: ...has not sufficient pressu re or flow rate Check DHW system Check flow meter filter Flow meter sensor is faulty or discon nected Replace or reconnect it Flow meter is blocked Replace it Burner does not...

Page 25: ...24...

Page 26: ...25...

Page 27: ...26...

Page 28: ...ax 39 0365 878 576 e mail fondital fondital it www fondital it The MANUFACTURER reserves the right to implement any necessary and or useful variation to products without modifying fundamental characte...

Reviews: