3.1

ELECTRONIC CONTROL BOX

The  boiler  is  supplied  with    HONEYWELL

S4565C electronic control box.

Ignition and flame detection is controlled by

an electrode located on the burner, which

guarantees  maximum  safety  with  interven-

tion times, for accidental switching off or

gas failure within one second (fig. 8).

3.1.1

Operating cycle

Normally the burner takes 1 or 2 seconds

to light. However, it is possible for ignition fai-

lures to occur, with consequent activation of

signal  indicating  that  the  control  box  has

“locked out”.

Gas failure

The  control  box  runs  through  the  cycle

normally  sending  electric  power  to  the

ignition  electrode.  The  electrode  conti-

nues  spark  discharge  for  a  maximum  of

10 sec. If the burner does not ignite, the

control box “locks out”.

This  may  occur  upon  first  ignition  or

after  long  periods  of  boiler  lay-off  when

there is air in the pipes. It may be caused

by the gas cock being closed or by one of

the valve coils having a break in the win-

ding, so that the valve cannot open.

The  ignition  electrode  does  not  emit

the spark

In the boiler you can only see that gas is

sent to the burner, after 10 seconds the

appliance is stopped. This may be due to

an  electrode  wire  that  is  broken  or  that

has not been properly fixed to the termi-

nal of the equipment; or the transformer

of the equipment may be burnt.

No flame is detected

From  the  time  of  the  starting  you  can

observe  the  electrode  continuos  spark-

ing even if the burner is on. After 10 sec-

onds the sparking stops and so does the

burner,  while  the  lock-out  lamp  appears

to be on.

It occurs if the phase and neutral position

on  the  terminal  board  has  not  been

observed.  The  detection  electrode  cable

is  disconnected  or  the  electrode  itself  is

earthed;  the  electrode  is  very  worn-out

and needs replacing.

The control box is defective.

The  sudden  lack  of  voltage  causes  the

immediate  shutdown  of  the  burner  and

when the voltage is restored the  boiler will

automatically restart.

3.1.2

Operating cycle

During each start-up the programmer car-

ries  out  self-checking  which  will  not  allow

s t a r t - u p   i n   c a s e   o f   d e f a u l t   o r   i f   a

parasitic  flame  signal  is  detected,  The  pro-

grammer will not start even if the air pres-

sure  switch  is  not  on  the  no-  ventilation

position.

3.2

SMOKE PRESSURE 

SWITCH 

(fig. 9)

The  pressure  switch  with  fixed  settings  is

able to guarantee the boiler operation even

with air intake and smoke outlet pipes at the

maximum limit of the length allowed

The  signal  value  at  the  pressure  switch  is

measured  by  means  of  a  differential  pres-

sure  gauge  that  is  connected  to  the  posi-

tive  and  negative  pressure  intakes  located

onthe hermetically sealed chamber.

3.3

HEAD AVAILABLE 

FOR THE SYSTEM 

Residual  head  for  the  heating  system  is

shown  as  a  flow  rate  function  in  the  graph

in fig. 10.

43

3

CHARACTERISTICS

2

1

3

Fig. 8

Fig. 9

500

1000

1500

2000

2500

0

100

200

300

400

500

Portata l/h

Pr

evalenza r

esidua (mbar)

BITHERM BF

3000

Fig. 10

KEY
1

Burner

2

Detection electrode

3

Ignition electrode

FLOW RATE l/h

RESIDU

AL

HEAD 

(mbar)

Summary of Contents for RX 26 BF

Page 1: ...ype of gas supplied Check that the flue pipe for the outlet of the products of the combustion is unobstructed and or has been properly installed Make sure that any shutoff valves are open Make sure th...

Page 2: ...BF Heat output min nom kW 23 2 31 0 kcal h 19 950 26 660 Heat input min nom kW 26 2 34 0 kcal h 22 530 29 240 Cast iron sections n 4 Water content l 15 Power consumption W 155 Maximum water head bar...

Page 3: ...ty valve goes into action When sizing gas piping from the meter to the boiler take into account both the volume flow rates consumption in m3 h and the relative density of the gas in question The secti...

Page 4: ...The boiler is supplied with the connections required for coaxial ducts that can be turned in any direction The maximum horizontal length of the duct must not exceed 2 8 meters Maximum two extensions c...

Page 5: ...alculation in that the sum of the head losses of the single fittings is less than 6 00 mm H2O Intake Outlet 6 meter horizontal pipe 80 x 0 20 1 20 6 meter horizontal pipe 80 x 0 40 2 40 n 2 90 elbows...

Page 6: ...o 35 kW distances in mm A below openable window 600 B below ventilation opening 600 C below eaves 300 D below balcony 1 300 E from adjacent window 400 F from adjacent ventilation opening 600 G from ho...

Page 7: ...nected to an efficient eathing system SIME cannot be held liable for damage to people or things that is due to non earthing of the boiler Always turn off the power supply before doing any work on the...

Page 8: ...continuos spark ing even if the burner is on After 10 sec onds the sparking stops and so does the burner while the lock out lamp appears to be on It occurs if the phase and neutral position on the te...

Page 9: ...ating pressure values have been changed After have ultimated the conversion of the boiler please stick onto the casing panel the plate showing the relevant feeding gas which is included into the kit N...

Page 10: ...operation The fan works but with less revolutions and therefore it does not enable the flue gas pressure switch replace it The principal burner does not burn prop erly flame too high yellow flame Mak...

Page 11: ...e if it is lower than 1 bar When the operation is over close the fill up cock GAS CONVERSION If the gas that is to be used if different than the one that the boiler has been prearran ged for contact a...

Reviews: