Specifications
Electrical
Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m).
Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 20 amps,
Maximum icemaker fuse – 20 amps each.
Model
Icemaker
Dispenser
number
amperage
amperage
Single-sided models
U300K
11.5 amps
U300KR400A/W
11.0 amps
10.5 amps
U300KR800A/W
11.0 amps ea (2)
11.5 amps
Plumbing
Dispenser
1" PVC slip joint for bin drain
1" PVC slip joint for beverage drain pan
1" PVC slip joint for beverage bath drain
Beverage connections
1/4" ID syrup beverage hose
3/8" 45° flair fitting for carbonator water inlet
1/4" ID CO
2
Note
: Set CO
2
pressure to 75 psi and syrup pressure to 60 psi.
Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected
to automatic fill dispensers.
Icemaker
(detailed specifications may be found in icemaker installation manual
packed with icemaker)
1/4" FPT water in
3/4" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
5