background image

Wiring diagrams

U300K series

YELLOW

YELLOW

M3

WHITE

BATHPUMP

MOTOR

(35 MIN ON DELAY)

DISPENSE

SWITCH

LID

PL1-1

L1

SWITCH

POWER

BLACK

POWER

BLACK

TOP LID

SWITCH

NO

C

BLACK

RED

RED

24V RED

PL6-1

C

M2

MTR

PURPLE

DISPENSE

PL1-2

DRAIN

PAN

SWITCH

C

GRAY

NO

ORANGE

7

4

R1

READY

AUGER MOTOR

RED

BLK

WHEEL MOTOR

PURPLE

PL2-1

RED

PL3-2

M1

BLUE

PL2-2

WHT

PL3-3

ORANGE

115 VOLTS

24 VOLTS

T1

BROWN

NO

PL6-3

BROWN

BATH CONTROL

BOARD

PURPLE

MTR

LID

READY

L2

BLK

PL5-1

PUMP

DISPENSE RELAY

A

R1

B

L2

WHT

L2

WHT

TERMINAL STRIP CONNECTION

PIN and SOCKET CONNECTION

PL5-2

24V YEL

LEGEND:

YELLOW

YELLOW

YELLOW

YELLOW

KEYSWITCH

PL1-4

NO

DRAINPAN

SWITCH

AUTOFILL OPTION

DISPENSE

BIN T'STAT

C

24VAC RED

BATH SOL

SENSOR

TEMP

RED

RED

T

RED

R1

6

9

PL6-2

1

RED

PL7-1

BEV HARN

PL1-3

RED

C

BROWN

BROWN

IM_#1

GREEN - COLD

RED - WARM

STATUS LIGHTS

BATH CONTROL BOARD

BATH SOL

24VAC YEL

NC

NO

BROWN

T-STAT

BLUE

2

PL6-4

BATH

SOLENOID

(12 SEC ON: 1 MIN OFF)

BLUE

PL4-2

PL4-1

SOLENOID

DISPENSE

PL4-3

PL4-4

Valve_8

24V JUNCTION BOX

BIN SIGNAL (24V)
ICEMAKER #1

BIN SIGNAL (24V)
ICEMAKER #2

Valve_3

SWITCH

IM_#2

BLACK

Valve_1

BLUE

BLUE

RED

BLUE

Valve_2

BLACK

Valve_6

Valve_7

Valve_4

BLACK

Valve_5

Valve_9

Valve_10

YELLOW

PL7-2

PUMP

CARB.

L1

L2

CARB.
TANK

CONTROL

COM

NO

CARB.

PUMP

WHITE

GRAY

GRAY

LOW HIGH COMMON

BLACK

RED

GREEN

14

Summary of Contents for U300K Series

Page 1: ...on and Service Manual U300K Series Integral Cold Carbonation Ice and Beverage Dispensers 00109181R00 801 Church Lane PO Box D Easton PA 18044 USA Toll free 800 523 9361 888 2 FOLLETT 610 252 7301 Fax...

Page 2: ...2...

Page 3: ...1 The equipment is new and unused 2 A return authorization number has been issued by customer service 3 Follett receives the equipment at the factory in Easton PA within 30 days of the issue of the r...

Page 4: ...mote icemaker s capacity and refrigerant 400 400 lbs 181kg day R404A 800 800 lbs 363kg day R404A absence of manual fill unit K Integral ice water bath cold carbonator equipped Approximate manual load...

Page 5: ...bath drain Beverage connections 1 4 ID syrup beverage hose 3 8 45 flair fitting for carbonator water inlet 1 4 ID CO2 Note Set CO2 pressure to 75 psi and syrup pressure to 60 psi Drains should be har...

Page 6: ...um between dispenser side s and optional icemaker s ICE disp drains conn electric entrance for beverage line carbonator pump 40 875 1039mm 25 25 642mm 29 625 753mm 54 875 1394mm 17 432mm 18 875 480mm...

Page 7: ...penser feet to floor 7 Adjust legs for 1 8 4mm clearance between dispenser lip and countertop to verify there is no load on flange 8 Apply a bead approximately 1 4 6mm in diameter of NSF listed silico...

Page 8: ...amps max fuse size each Field wiring diagrams Note Field wiring diagrams are intended to aid electricians or technicians in understanding how equipment works All field wiring must be installed in acc...

Page 9: ...empty bath and submerge coils Coils are submerged when water starts to flow out overflow drain DO NOT SPLASH WATER ON ELECTRICAL BOX Once filled with water add ice to bath until ice covers top of wate...

Page 10: ...chute where it drops by gravity into the container In automatic load units ice is manufactured in either one or two Follett remote icemakers These icemakers may be located up to 20 ft 6m away from th...

Page 11: ...23L of cleaning Solution A Fill a clean product tank with cleaning solution Fill a second clean product tank with potable rinse water 1 Disconnect all syrup lines from product containers 2 Connect syr...

Page 12: ...lity connection side of dispenser from mounting bracket and drain ice water bath 9 Use a bottle brush to clean coils with Solution A rinse and sanitize with Solution B 10 Reposition ice water bath dra...

Page 13: ...chute and gate toward you and out through panel opening 7 Lift dispenser mechanism assembly off auger and auger tube Auger and auger tube removal 1 Remove dispense chute cover and auger motor assembl...

Page 14: ...ECTION PL5 2 24V YEL LEGEND YELLOW YELLOW YELLOW YELLOW KEYSWITCH PL1 4 NO DRAINPAN SWITCH AUTOFILL OPTION DISPENSE BIN T STAT C 24VAC RED BATH SOL SENSOR TEMP RED RED T RED R1 6 9 PL6 2 1 RED PL7 1 B...

Page 15: ...N position check connections 2 Replace switch 3 Replace transformer 4 Check pan and reseat 5 Replace switch 1 Check connections 2 Check linkage 3 Replace solenoid 1 Check connections 2 Check auger mot...

Page 16: ...be warm Solution 1 Check carbonator pump power at plug and at level control board 2a Check connection between low level electrode and level control board 2b Check ground wire on carbonator tank 3 Repl...

Page 17: ...l be dispensed into the waterbath for 12 seconds then stop for 60 seconds The pump will stay energized and the circuit board will then monitor the water temperature If it is below the set point the Gr...

Page 18: ...9 Thumbscrew 10 32 1 2 splash guard 501100 Not shown Switch dispense PB 502441 Not shown Switch dispense lever includes boot and spacer 501714 Not shown Boot dispense switch button lever 501841 Not s...

Page 19: ...motor bracket 501982 Not shown Pin quick release wheel motor 2 required 502102 10 Drive shaft assembly for Brother motor 502630 11 Agitator rods fixed front and back 502629 12 Wheel dispense 501978 1...

Page 20: ...dispense 501955 2 Linkage pin gate solenoid 502096 3 Pin quick release 3 77mm gate and lever 501949 4 Chute ice 501952 5 Solenoid 501961 Not shown Boot solenoid 502098 6 Dispense mechanism assembly 50...

Page 21: ...red 501966 9 Fitting beverage valve 00111492 10 Clamp Oteicker 1 4 00106914 11 Tubing beverage 1 4 order by foot 00111500 12 Water probe high level red 00107409 13 Water probe low level black 00107417...

Page 22: ...72 4 Switches power and icemaker 502209 5 Board circuit and probe one unit 502473 6 Bracket probe 00111484 7 Switch safety 502511 Not shown Switch safety drain pan assembly LH unit 502500 Not shown Sw...

Page 23: ...23...

Page 24: ...00109181R00 1 03 801 Church Lane PO Box D Easton PA 18044 USA Toll free 800 523 9361 888 2 FOLLETT 610 252 7301 Fax 610 250 0696 www follettice com UL UL C...

Reviews: