Specifications
power cord
air exhaust
16.00
"
(40.7 cm)
4.00
"
(10.2 cm)
3/8
" FPT
water inlet
3/4
" MPT drain
23.5
"
(59.7 cm)
18.00
"
(45.8 cm)
32.00
"
(82.6 cm)
air
intake
Front View
Side View
Rear View
22.625
"
(57.5 cm)
Electrical
§
230 V, 50 Hz, 1 phase, 5 .5A or 220 V, 60 Hz, 1 phase, 5 .5A
§
Connect to a dedicated circuit .
Ambient
Air temp*
100 F/38 C Max .
50 F/10 C Min . Best performance below 80 F (27 C)
Water temp
†
90 F/32 C Max .
45 F/4 C Min . Best performance below 70 F (21 C)
Water pressure
70 P .S .I ./5Bar Max .
10 P .S .I ./0 .7 Bar Min .
* Ambient air temperature is measured at the air-cooled condenser coil inlet .
†
Ambient water temperature is measured in the ice machine reservoir .
Plumbing
12CI425A
Dispenser drain
3/4" MPT
Water inlet
3/8" FNPT
Note: Water shut-off recommended within 10 ft . (3 m) of dispenser . Drain to be hard-piped and insulated . Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope .
Ventilation clearances
§
6" (15 .3 cm) on right side of dispenser, 6" (15 .3 cm) at top for ventilation and 12" (30 .5 cm) at top recommended
for service .
Note: Do not block right side air intake or top air exhaust .
Dry weight
§
175 lb (79 .4 kg)
4
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz