CAUTION!
§
Wear rubber gloves and safety goggles (or face shield) when handling cleaner/sanitizer .
§
Use only Follett approved cleaners .
§
It is a violation of Federal law to use SafeCLEAN Plus™ in a manner inconsistent with its labeling .
§
Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser .
SafeCLEAN Plus Solution: Mix cleaning solution of 1 gal . (3 .8 L) 100 F (38 C) water and 7 oz (198 g) (one 7 oz
packet) of Follett SafeCLEAN Plus .
Cleaning & sanitizing tool checklist
§
(1) 1 .5 Gallon (or larger) Plastic Buckets
§
(2) clean cloths
§
Sanitary gloves
§
Safety glasses
§
(2) Sani-Sponge™ (P/N 00131524 - single sponge)
§
(1 ) Packet of SafeCLEAN Plus (P/N 01050863 - 24 packets)
Cleaning/descaling and Sanitizing Procedure
Note: Before beginning cleaning process, check drains and drain cup to ensure they are open and flowing freely .
1. If ice machine was running recently, ensure that the evaporator is completely free of ice before
proceeding . If there is ice in the evaporator, complete steps 2-7 using only hot water to remove the ice
then begin Cleaning/Descaling Procedure again .
2. Remove front cover and turn OFF bin signal switch .
3. Dispense all ice from storage hopper and discard .
4. Remove top of machine and hopper lid .
5. Press CLEAN switch . The MAINTENANCE light will turn on and the machine will drain . Wait for the LOW
WATER light to turn on .
6. Remove lid from cleaning cup and fill (about 1 quart) until SafeCLEAN Plus solution overflows from the
ice transport tube into the hopper . Place lid back on cup . Save remainder of the solution .
7. CLEANER FULL light will turn on and machine will start cleaning and sanitizing cycle then rinse three
times; this process takes approximately 15 minutes .
8. While ice machine is cleaning/descaling and sanitizing, clean dispenser as follows:
a . Remove center thumbscrew, locking plate, two wingnuts and backing plate from front of storage hopper .
b . Remove stud assembly, baffle, wheel, and any remaining ice .
c . Remove dispense chutes from splash panel .
d . Submerse drain grille in SafeCLEAN Plus solution and allow to soak to remove any scale buildup .
e . Wipe stud assembly, baffle, wheel, inside of storage area, dispense chutes, drain grille and drain pan with
damp cloth wrung out in SafeCLEAN Plus solution . Thoroughly rinse all parts with damp cloth wrung out
with clean water .
Note: To avoid possible damage to motor assembly, only use a damp cloth to clean storage hopper . Do not
allow water to run through motor shaft hole in bottom of hopper .
f . In the following order, reinstall dispense chutes, wheel, baffle, backing plate, two wing nuts, stud assembly,
locking plate, and thumbscrew . (See manual for correct baffle position .)
9. Loosen Phillips-head screw on nozzle connected to evaporator . Remove nozzle from evaporator side only,
leave other side of nozzle connected to transport tube .
10. Place one Sani-Sponge in remaining SafeCLEAN Plus solution .
11. Insert the sponge soaked in SafeCLEAN Plus solution into nozzle then insert a dry sponge into the
nozzle .
E12CI425A 230 V 50 Hz, C12CI425A 220 V 60 Hz 9