8. Remove utility knock-out (Fig.4, 5F) from rear of dispenser and install supplied protective grommet. For dispensers
using remote icemakers, remove ice transport tube knock-out (Fig. 5G) from rear of dispenser.
9. Run water supply line from back through utility knock-out (Fig. 5F) and connect water supply line to 3/8" FPT fi tting
on utility fl ange at bottom of dispenser (Fig. 3G).
10. Connect and run a dedicated drain line from 3/4" drain tube to wall or fl oor drain. An air break should be provided.
11. Proceed with either remote or top-mounted icemaker connection instructions, as appropriate.
wall bracket – bottom view
3.5" (89mm)
1.375"
(35mm)
4.75"
(121mm)
3.5" (89mm)
11.5"
(292mm)
16"
(406mm)
access opening
cover
wall stud
25HT400A/W
25.5"
(648mm)
50HT400A/W
29.5"
(749mm)
25HT400A/W
9.5" (241mm)
50HT400A/W
11.5" (292mm)
25HT400A/W
9.5" (241mm)
50HT400A/W
11.5" (292mm)
utility
cut-out
wall bracket
3/8" fasteners
20.875"
(530mm)
17.8"
(445mm)
filler strip
Fig. 8 – Mounting dimensions with wall mount units
without drain pan with integral icemaker
wall bracket – bottom view
wall bracket
3.5" (89mm)
1.375"
(35mm)
4.75"
(121mm)
3.5" (89mm)
11.5"
(292mm)
3/8" fasteners
16"
(406mm)
access opening
cover
wall stud
25HR400A/W
25.5"
(648mm)
50HR400A/W
29.5"
(749mm)
25HT400A/W
9.5" (241mm)
50HT400A/W
11.5" (292mm)
25HT400A/W
9.5" (241mm)
50HT400A/W
11.5" (292mm)
utility
cut-out
Fig. 7 – Mounting dimensions for wall mount
units without drain pan with Satellite-fi ll icemaker