Maestro 400 Series Top Kit for Lancer
13
23. Connect the ice transport tube(s) to the dispenser:
a)
Drill 3/16" (5mm) holes through both sides of the tube
1/2" (13mm) from the tube end.
b)
Collapse tube and insert through gasketed hole (Fig. 7).
c) Match tube holes to bracket tabs.
24. Route bin thermostat capillary tube from the 4" x 4"
(102mm x 102mm) junction box into bin alongside the ice
transport tube. Secure capillary tube into bracket (Fig. 7).
25. Reinstall the dispenser cover with supplied screws (Fig. 13).
26. Install telescoping chase (RIDE model ice machines only).
a)
Mount lower chase section to chase bracket on counter
with supplied screws (Fig. 14.1).
b) Position upper chase section over lower chase section.
Align top of upper section to top of stainless dispenser top
(Fig.
14.2).
c) Drill pilot holes on both sides of chase and secure with
supplied screws (Fig. 14.3).
27. Turn ice machine power and water on.
28. After ice machine has made ice for approximately 15 minutes
complete the following start-up checks:
a)
Dispense
ice.
b)
Hold ice on bin thermostat and make sure
ice machine shuts off.
c) Remove ice from bin thermostat and make sure
ice
machine
restarts.
Note:
Ice machine has a 20 minute restart delay.
Fig. 13
1
1
2
3
3
1
Fig. 14