Maestro 400 Series Top Kit for Lancer
11
RIDE model ice machine installation
18. Ice transport tube chase may be located behind
or to either side of the dispenser (Fig. 9 and 10).
Using the chase mounting bracket as a template
mark the counter for the ice transport tube(s)
in one of the locations shown in Fig. 9 and 10.
Within the template outline drill one 2.25" (58mm)
to 2.375" (61mm) hole for each ice transport
tube. Secure the chase mounting bracket to the
counter using supplied screws (Fig. 11).
Fig. 9 – Single ice tube dispensers
Fig. 10 – Double ice tube dispensers
2.25" (57 mm) -
2.375" (61 mm)
dia. hole
typical
1.25
(32 mm)
1.25" (32mm)
1.25"
(32 mm)
1.50" (38 mm)
1.50" (38 mm)
front
side entr
y
chase
side entr
y
chase
rear entry chase
4.50" (115 mm)
4.50" (11 5mm)
A
B
6"
(153 mm)
2.25" (57mm) -
2.375" (61mm)
dia. hole
typical
1.25
(32mm)
1.25" (32mm)
1.25"
(32mm)
3" (77mm)
3" (77mm)
front
side entr
y
chase
side entr
y
chase
rear entry chase
A
B
6"
(153mm)
Fig. 11
Dimension A
Dimension B
Single tube – Fig. 9
22" (559mm) dispenser
11.00" (280mm)
8.00" (204mm)
30" (762mm) dispenser
15.00" (381mm) 12.00" (305mm)
Double tube – Fig. 10
22" (559mm) dispenser
9.50" (242mm)
8.00" (204mm)
30" (762mm) dispenser
13.50" (343mm) 12.00" (305mm)