Maestro 400 Series Top Kit for Lancer
Specifi cations
Electrical
Model
number
Full
load
amps
Max.
fuse
size
MC400
series
ice
machine
115/60/1 11.0
amps
20
amps
Ambient specifi cations
Air temperature
100 F/38 C max.
50 F/10 C min. (best performance below 80 F/27 C)
Water temperature
90 F/32 C max.
40 F/4 C min. (best performance below 70 F/21 C)
Water pressure
70 P.S.I. max. (482kPA) 10 P.S.I min. (89kPA)
Plumbing
Your new ice machine is equipped with a drain line to simplify draining the evaporator and fl oat reservoir. The
tube labeled “fl oat/evap drain” is for
SERVICE USE ONLY
and must
NOT
be connected to the ice machine drain.
Water line sizes
Make up water (inlet to fl oat)
1/4" min.
Condenser
(water-cooled
only)
3/8"
min.
Drain line sizes
Ice machine drain
3/4" min.
Condenser
(water-cooled
only)
1/2"
min.
Slope to drain
1/4" per foot (6mm per 30.4cm run)
1/2" min.
•
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
•
Separate drains for ice machine and condenser. To prevent back fl ow, do NOT connect drains.
•
Follett recommends a Follett water fi lter system be installed in the ice machine inlet water line (standard
capacity #00130299, high capacity #00978957, carbonless high capacity #01050442).
Field Wiring: countertop and wall mount dispensers with RIDE
®
remote ice
delivery model ice machines
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.