ICE MANAGER
remote condensing
Connect utilities to docking assembly.
5
External connections
CAUTION
• Plug must be accessible after final installation.
Refrigerant
5.2
➊
• Braze supplied quick-connect lines onto
stub-ins
➊
.
• Plug must be removed from John Guest
fitting.
• Route 3/8" drain tubing through knockout
in back of docking station and insert fully
into John Guest fitting connection at the
rear of the machine chassis. Route other
end of 3/8" drain tubing to drain.
• Drain must slope 1/4" inch per foot (6 mm
per 30,4 cm).
Chassis drain plumbing - required
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
➍
3/4" MPT x 1" slip
➎
➌
➋
➊
➏
• Rough-in ice machine potable water
supply
➊
. 3/8" push-in connection will be
made at included shut-off valve then at
back of docking station into solenoid.
• Remove access panel if necessary
➋
.
• Connect the silicone tubing to the ice
machine 3/4" drain barb
➌
.
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
➍
.
• Connect the 1" slip fitting to the 1" stand
pipe/drain
➎
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4 mm/0,3 m).
• Apply Petrol-gel to barbed drain fitting
➏
• Replace access panel.
Water and flush drain
5.1