4 Specifications
00981795R03 – REF20/25 LB, PL
Standard features – all models
Door
Solid, insulated, stainless steel
Door handle
ADA-compliant, full length handle with integral lock
Interior/exterior material
Heavy-duty, corrosion resistant stainless steel
Casters
(4) dual-wheel swiveling casters with toe locks
Insulation
2.75" (7 cm) thick, CFC-free foam insulation throughout
Air circulation system
Ducted air through back plenum openings (16 - PL, 12 - LB) with front face return
Temperature probe
Stainless steel RTD (resistance temperature detectors). One at top on all models. One
at bottom on PL models
Ambients
Intended for indoor use where ambient temperature does not exceed 86 F (30 C) and ambient relative humidity
does not exceed 60% RH.
Clearances
To ensure proper ventilation of the refrigeration system, the following clearances are required:
§
16 inches (41cm) above the freezer
§
2 inches (5cm) behind freezer
§
9 inches (23cm) on the left side. If the ambient is <86 F (30 C), no side clearance is required.
Electrical specifications
§
120 V, 60 Hz, 1 phase
§
Full load amps: 12FLA, 67 LRA compressor
§
Minimum circuit ampacity: 25A with max 60 ft. (18.2 m) wire run between receptacle and breaker using
minimum 12 AWG
§
Minimum voltage at compressor terminals: 97 Vac when energized
§
Maximum size of branch circuit overcurrent device: 20A dedicated circuit
Refrigeration specifications
Refrigerant R404a, 10.6 oz (300 g)
Detail drawing
FZR20
30.5" (78 cm)
FZR25
36.5" (93 cm)
76.75"
(195 cm)
79.5"
(202 cm)
29.75"
(76 cm)
16.0"
(41 cm)
Required Clearances
1.0" (3 cm) or
2.0" (6 cm) if
outlet located
directly behind
freezer)