![Follett chewblet 15CI100A Installation, Operation And Service Manual Download Page 5](http://html1.mh-extra.com/html/follett/chewblet-15ci100a/chewblet-15ci100a_installation-operation-and-service-manual_2314926005.webp)
15CI100A with Rear Drain 5
Water
WARNING!
Connect to potable water supply only.
§
Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§
Not recommended for use with softened water
Clearances
§
3" (7.62 cm) behind and on each side of dispenser for electrical and connection and ventilation
Electrical
§
115 V, 60 Hz, 1 phase, 5A, maximum fuse 15A
§
Connect to dedicated 15A circuit, fuse or breaker
§
Must be grounded - requires 3-prong outlet. Do not remove ground.
Refrigeration
WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage dispenser.
§
Refrigerant R134a – 5.0 ounces (142 grams)
Heat Rejection
§
1700 BTU/hr (498 W)