15CI100A with Rear Drain
11 . Locate the storage bin drain tube pinch clamp (Fig . 10) and
engage (close).
12 . Pour SafeCLEAN Plus solution into bin lid access spout
until solution reaches
and remains level
at the spout
neck. (Because the cleaning solution reaches the internal
components via overflow into the ice transport tube, it is
necessary to add cleaning solution until it remains level at
the spout neck.)
13 . Allow the SafeCLEAN Plus solution to remain in unit for 15
minutes.
14 . While machine is cleaning, remove top and right side panel
to access and clean air-cooled condenser.
15 . Submerge ice dispense chute in the remainder of
SafeCLEAN Plus solution for 2 minutes. Rinse with clean,
potable water.
16 . Drain system: (1) release (open) the storage bin drain tube
pinch clamp and (2) lower water reservoir drain tube into
bucket.
17 . Secure capped water reservoir drain tube into holder and
engage (close) storage bin drain tube pinch clamp.
18 . Fill and drain three times with potable water. Secure water
reservoir drain tube and release (open) the storage bin
drain tube pinch clamp.
19 . Place a bucket under the dispense chute and remove cap.
Note: Some solution will remain and drain out when cap is
removed. Reposition cap on bin lid spout.
20 . Reinstall front panel, ice dispense chute, and drip tray.
21 . Press and hold maintenance/clean switch to exit
Maintenance Mode.
Fig . 10
Pinch clamp shown
installed internally.
User Interface and Exterior Cabinet
1 . Press and release maintenance/clean switch so that only "FRESH FILTERED ICE AND WATER" displays
in the user interface to enter Cleaning Mode (and disable dispensing).
2 . Plastic parts, including the user interface, can be cleaned with a non-abrasive glass cleaner. Clean
stainless steel panels with stainless steel cleaner.
3 . Press and release maintenance/clean switch to put unit back into service.
Summary of Contents for chewblet 15CI100A
Page 24: ...24 15CI100A with Rear Drain Condenser Fan Motor Removal 7 Series Shown...
Page 28: ...28 15CI100A with Rear Drain Parts 15 Series Exterior 6 4 7 5 3 1 2 8 x6 8 x2 8 x2...
Page 30: ...30 15CI100A with Rear Drain 15 Series Interior 3 4 7 1 10 10 5 6 11 9 8 2 12 13 14...
Page 32: ...32 15CI100A with Rear Drain 15 Series Bin Assembly 6 2 1 7 8 5 3 4 9 10 11...
Page 34: ...34 15CI100A with Rear Drain Evaporator Assembly 6 4 3 1 9 5 2 14 13 13 10 11 12 8 7...