20
7CI100A/7FS100A, 15CI100A/15FS100A
7. Install compression nozzle:
§
Remove and inspect compression nozzle O-ring seal.
Replace if damaged in any way.
§
Clean O-ring groove. Lubricate O-ring with Petrol-gel and
reinstall.
§
Install compression nozzle
(Fig. 26.1).
§
Install compression nozzle retainer
(Fig. 26.2).
§
Install M6 socket head allen screw
(Fig. 26.3).
Fig. 26
2
1
3
8. Install transport tube (Fig. 27.1).
9. Tighten hose clamp (Fig. 27.2).
Fig. 27
1
2
10. Install gear motor:
§
Install main housing insulation
(Fig. 28.1).
§
Slide gear motor onto auger shaft
(Fig. 28.2).
§
Install two M6x90 allen screws
(Fig. 28.3).
Fig. 28
3
3
2
1
Summary of Contents for 7CI100A
Page 26: ...26 7CI100A 7FS100A 15CI100A 15FS100A Condenser Fan Motor Removal 7 Series Shown...
Page 30: ...30 7CI100A 7FS100A 15CI100A 15FS100A Parts 7 Series Exterior 2 1 3 5 6 4 7 8 x4 8 x2 8 x2...
Page 32: ...32 7CI100A 7FS100A 15CI100A 15FS100A 7 Series Interior 4 7 12 1 3 5 6 11 10 10 2 9 8...
Page 34: ...34 7CI100A 7FS100A 15CI100A 15FS100A 15 Series Exterior 6 4 7 5 3 1 2 8 x6 8 x2 8 x2...
Page 36: ...36 7CI100A 7FS100A 15CI100A 15FS100A 15 Series Interior 4 7 1 3 10 5 6 9 8 2 10 11 12...
Page 44: ...44 7CI100A 7FS100A 15CI100A 15FS100A Base Stand 1 2...
Page 46: ...46 7CI100A 7FS100A 15CI100A 15FS100A...