DP48 User Guide Page
9
4.0 Rear Panel Functions
1.
Main Power
- Connects via a standard IEC socket. A compatible power
cord is supplied with the unit. The voltage input is 110V~240VAC, 50-60Hz.
2.
Main Fuse
- T2.5A-250V. Slow blow type.
3.
Power switch
- Controls power On/Off.
4.
RS485
– Let remote control the device’s up to 1000M and connect
devices in serial up to 250 sets (Optional USB to RS485 adapter is
available)
5.
XLR input and outputs -
Separate 3-pin XLR connectors are provided
for each audio input and output. The device's output stage employs the
balanced impedance topology. All I/O connectors have pin 1 as ground
(shield), pin 2 as + and pin 3 as -.
5.0 Powering Up the Device
•
After powering up the unit, the following initialization screen is displayed
on the LCD:
•
The initialization process takes about 8 seconds and during that period
the unit boots and displays the device model and firmware version.
•
After the initialization process is finished the DP48 displays its main
screen:
•
The screen shows the current program number and program name
assigned to the unit. If the 2 fields are empty, it means that no program
is assigned, the last data before previous power down is recalled instead.
•
Now the DP48 is ready to operate.
5 Output
4
2
1
3
5 Input