TView Pro AV 1600 User's Manual Rev 1.02
27
range for each register. Each command ( i. e. Register Number Byte, followed by Value Byte) must be concluded with
a Carriage Return.
The Value Byte provides “absolute information” if the parameter in question is a Toggle or Multiple Choice Item. If
the parameter in question is a range item, the Value Byte provides “relative information” incrementing or
decrementing the existing value of that parameter by on count.
In addition to the above commands, two additional commands are provided for control information. Writing Value
Byte = 01 to register 22 will cause an Auto Reset operation to occur. Writing Value Byte = 01 to register 23 will cause
the existing parameter set to be written in to NOVRAM. The TView Pro AV 1600 will power up with these parameters
until the NOVRAM is changed by writing another set of parameters.
The following table indicates the Register Functions, the Register Number, Parameter Type and action of the legal
values of the Value Byte.
Register Name
Number Type
Value Byte Actions
Horizontal Position
1
Range
=01 increment,
=00 decrement
Horizontal Size
2
Range
=01 increment,
=00 decrement
Vertical Position
3
Range
=01 increment,
=00 decrement
Vertical Size
4
Range
=01 increment,
=00 decrement
Zoom
5
Toggle =01 Zoom On,
=00 Zoom Off
UnderScan
7
Toggle =01 UnderScan, =00 OverScan
Terminate
8
Toggle =01 Terminated, =00 Unterminated
Fine Genlock H Position
9
Range
=01 increment,
=00 decrement
Coarse Genlock H Position
10
Range
=01 increment,
=00 decrement
Genlock Subcarrier Phase
11
Range
=01 increment,
=00 decrement
Genlock Subcarrier Phase Reverse 12
Toggle =01 180 degrees, =00 0 degrees
Genlock Termination
13
Toggle =01 Terminated, =00 Unterminated
NTSC/PAL
14
Toggle =01 NTSC,
=00 PAL
Flicker Filter
15
Multiple =00 Off
=07 Maximum
Brighntess Boost
17
Toggle =01 Boost On,
=00 Boost Off
Freeze Frame
19
Toggle =01 Freeze,
=00 Live Input
YUV/RGB Selection
20
Toggle =01 RGB,
=00 YUV
Sync Selection
21
Multiple =01 GRN,
=02 VGA,
=03 MAC
Reset
22
=01 Reset
NOVRAM Save Parameters
23
=01 Save
Keyboard Lock
24
Toggle =00 Unlocked
=01 Locked
IR Remote
25
Toggle =00 Disabled
=01 Enabled
Test Pattern
26
Toggle
=00 Disabled
=01 Enabled
Brightness
27
Range
0-127
Contrast
28
Range
0-127
Saturation
29
Range
0-127