H. COUNTDOWN TIMER

ON/SETTING:

1. Press and hold   button until   displayed,  

  and hour flashes.

2. To select hour press   or   button.

3. To confirm press   button. Minutes flash.

4. To select minutes press   or   button.

5. To confirm press   button or wait.

OFF:

Press   button,   and countdown time 

disappear.

NOTE: At end of countdown time period, the fire shuts off. The Countdown 

   

Timer only works in Manual, Thermostatic, and Eco Modes.  

   

Maximum countdown time is 9 hours and 50 minutes.

I. MODES OF OPERATION

 Thermostatic Mode

The room temperature is measured and 

compared to the set temperature. The flame 

height is then automatically adjusted to 

achieve the set temperature.

 Program Mode

PROGRAMS 1 and 2, each can be 

programmed to go on and off at specific times 

at a set temperature.

 Eco Mode

Flame height modulates between high 

and low. If the room temperature is lower 

than the set temperature, the flame height 

stays on high for a longer period of time. If 

the room temperature is higher than the set 

temperature, the flame height stays on low 

for a longer period of time. One cycle lasts 

approx. 20 min.

J. THERMOSTATIC MODE

ON:

Press 

 button.   displayed, preset 

temperature displayed briefly, and then room 

temperature displayed.

OFF:

1. Press   button.

2. Press   or   button to enter Manual Mode.

3. Press   button to enter Program Mode.

4. Press   button to enter Eco Mode.

SETTING:

1. Press   button and hold until   displayed, 

  temperature flashes.

2. To adjust set temperature press   or 

 

 button.

3. To confirm press   button or wait.

K. PROGRAM MODE

ON:

Press   button.  , 

1

 or 

2

 , 

ON

 or 

OFF

 

displayed.

OFF:

1. Press   or   or   button to enter Manual 

 Mode.

2. Press   button to enter Thermostatic Mode.

NOTE: The set temperature for Thermostatic Mode is the temperature for 

   

the on time in Program Mode. Changing the Thermostatic Mode set 

   

temperature also changes the on time temperature in Program Mode. 

User instructions

Summary of Contents for Curvifocus

Page 1: ...CURVIFOCUS _____ INSTALLATION SERVICING AND USER INSTRUCTIONS...

Page 2: ...surfaces and as such should not be touched The front windows and surrounds are not considered to be fully secure guards against accidental contact It is recommended that an approved fire screen be use...

Page 3: ...e limits Ambient battery temperature range 32 F to 131 F 0 C to 55 C New and old batteries and different brands of batteries should not be used together Mixing of various batteries can cause the batte...

Page 4: ...buttons simultaneously Minutes flash 6 To select minutes press or button 7 To confirm press and buttons simultaneously or wait E CHILD PROOF ON To activate press and buttons simultaneously displayed a...

Page 5: ...button ignition operation by pressing and holding button for 10 sec immediately after installing batteries ON is displayed and 2 is flashing When change is complete 2 will change to 1 NOTICE If the p...

Page 6: ...om temperature is lower than the set temperature the flame height stays on high for a longer period of time If the room temperature is higher than the set temperature the flame height stays on low for...

Page 7: ...tinue to PROGRAM 2 and set on and off times or stop programming at this point and PROGRAM 2 remains deactivated NOTE PROGRAM 1 and 2 use the same on Thermostatic and off temperatures for and Daily Tim...

Page 8: ...ppliance at the rear CLEANING AND MAINTENANCE This appliance should be inspected and serviced once a year by a qualified competent and registered person The inspection and maintenance must at least en...

Page 9: ...cept and responsibility for the proper and safe working of the appliance The flue system must be constructed from the appliance upwards with all joints being fully locked and sealed using the Focus sp...

Page 10: ...0 H From an internal or external corner 600 I Above ground roof or balcony level 300 J From a surface facing the terminal 600 K From a terminal facing the terminal 600 L From an opening in the car por...

Page 11: ...65mm V H 0 4 opening R fully open G VERTICAL ROOF VENT TERMINATION C31 Flue sizing 100 150 Connector on Appliance for Poujoulat PGI concentric flue system 100 150 Adaptor for Metaloterm Ontop or Mueli...

Page 12: ...n arranging the Media into the Firebed it is imporant that the Pilot area is kept clear and that no Media enters the Pilot shield The Pilot area includes the pilot shield and the top of the burner to...

Page 13: ...LAY Scatter the Bags of Embers over the top of the burners as shown keeping the piot area clear Position Logs C1 C2 C3 as shown in the diagram Position Log C4 as shown in the diagram Installation inst...

Page 14: ...and burner pressure 1 Turn off the gas valve on the appliance 2 Release the screw on the Inlet Pressure test point on the gas valve and connect a manometer 3 Check that the measured pressure is as th...

Page 15: ...sites When using a vacuum cleaner it is recommended that one with a HEPA filtering system is used Re fit the Firebed arrangement re seal the appliance and check the safe operation of the appliance SER...

Page 16: ...I2H G20 at 20 mbar I3 G31 G31 at 28 37 mbar I3P 37 G31 at 37 mbar I3B P 30 G30 G31 at 30 mbar HU Hungary I3B P 30 G30 G31 at 30 mbar HR Croatia I2H G20 at 20 mbar I3P 37 G31 at 37 mbar I3B P 30 G30 G...

Page 17: ...0 892 Burner Pressure hot mbar 14 2 14 2 17 8 14 2 17 8 Injector Marking 650 Pilot 446 1385 44 Efficiency Class 2 Nox Class 5 Curvifocus LPG Gas type G30 G31 G31 I3B P 30 50 I3 I3P 37 50 I3P 30 Supply...

Page 18: ...18 DIMENSIONS 360 521 919 1800 150 280 1203 1000 A 100 150 219 DETAIL A CURVIFOCUS Technical Information...

Page 19: ...n new code reset See label on receiver Transmitter distance limited 1 Straighten the antenna 2 Replace receiver See wiring diagram p 23 2 Magnet unit is energized audible thud to detect functionality...

Page 20: ...d all metal parts Shorten IGN cable if possible or cover e g silicon hose See wiring diagram p 23 No IGN sequence stops no pilot flame No reaction to transmitter command Controller crashes Press RESET...

Page 21: ...pilot stays lit No Resistance in thermo current circuit too high Check cable in thermo current circuit See wiring diagram p 23 Magnet unit drops audible sound Not enough heat on thermocouple Check pos...

Page 22: ...gement of thermo couple Check installation OK 9 Magnet unit drops while motor turns 3 beeps No Low batteries Replace receiver batteries with 1 5V AA quality alkaline batteries System can be switched O...

Page 23: ...23 WIRING DIAGRAM Appendix...

Page 24: ...described here are in accordance with the appliances described in the EC Type Examination Certificate No UK LHD 0359 0657R1 delivered by INTERTEK and comply with the essential requirements applicable...

Page 25: ...25 Note...

Page 26: ...26 Note...

Page 27: ...27 Note...

Page 28: ...tion dition Distribution Atelier dominique imbert S A S au capital de 102 355 euros 34380 Viols le Fort France Tel 00 33 0 4 67 55 01 93 Fax 00 33 0 4 67 55 77 77 Web www focus creation com Email info...

Reviews: