The appliance features a hinge assembly which is supplied pre-

assembled. The hinge assembly should be fitted onto the rear of the

glass facia, on the lower right hand side as follows;

1) Before fitting the glass facia to the fire, attach the short end to the

bracket on the rear of the glass facia using the screw, nut and nylon

washer provided.

2)  Attach the long end of the hinge to the stud as shown. Secure using

the nut provided. All nuts should be tightened fully, and then released

one quarter of a  turn.

After commissioning the appliance, the customer should be instructed
on the safe use of the appliance and the need for regular servicing.
Frequency of service depends on usage, but MUST be carried out at
least once annually.
Advise that cleaning of the fire may be achieved when the fire is cold
using a damp cloth and mild detergent on most surfaces.
Advise that the fire will emit a "newness" smell for a time after initial
commissioning and that extra ventilation may be needed during this
time. Recommend that a guard be used for the protection of the young,
pets, the elderly and the infirm.

Isolate the fire from the gas supply.  Ensure that the fire is fully cold
before attempting service.  A suggested procedure for servicing is
detailed as follows;

1. 

Lay out the dustsheet and tools.

2. 

Remove the front glass facia as described in section 15.0, 
only in reverse.

3.

Remove the glass door assembly (4 screws) and clean
carefully. Remove the valve cover plate (4 screws).

4.

Inspect the burner and the catalysts and clean if necessary
with a soft brush.

5. 

Disconnect the gas supply.

6. 

Undo the four screws retaining the burner support brackets

to 

the base and rear of the firebox. 

7. 

Remove the burner unit, strip off the burner pipes and clean

thoroughly.

8. 

Clean the in-line restrictor, pilot assembly and the burner
tube. Do not attempt to remove the pilot injector as this can
cause damage.

9. Re-assemble 

components.

10. 

Turn on the gas supply and leak test. Check pilot and
burner for good ignition.

11.

Refit the valve cover and retaining screws.

12. 

Refit the glass door assembly, ensuring a good seal.

13. 

Refit the facia Refitting as described in section 15.0.

14. 

Check the purpose provided ventilation is unobstructed. 

15. 

Light the fire and test setting pressures.

16. 

Check safe operation of the appliance. 

For specific servicing instructions, see relevant sections.

First, remove the front Glass facia as described in Section 15.0 only in
reverse, remove the valve cover (4 screws) and disconnect the gas
connection inside appliance. The gas connections to the gas valve can
now be released. Undo the four screws retaining the burner brackets to
the base and rear of the firebox. The burner may now be removed.

Remove the pilot and main burner pipes and blow through to dislodge
any debris. Now remove the in line restrictor and blow through to make
sure it is entirely clear. 

Unclip the pilot lint gauze and clean with a soft brush. Clean the
exterior of the pilot assembly with a soft brush and blow through the
flame ports on the pilot head. Check the aeration holes are free from
lint or dirt. The pilot assembly can be removed if required by
disconnecting the electrode HT lead, gas pipe, thermocouple lead and
unscrewing the mounting screws and lifting away.  

16.0 BRIEFING THE CUSTOMER

WARNING: DO NOT ADD LOGS OR ORNAMENTS
SUCH AS PINE CONES, VERMICULITE OR ROCK
WOOL. USING THESE ADDED ITEMS CAN CAUSE
SOOTING.

17.0 SERVICING

18.0 SERVICING THE BURNER

WARNING: ANY CHANGE TO THIS HEATER OR ITS
CONTROLS CAN BE DANGEROUS.

M4 nyloc nut

Nylon washer

Retaining stud

M4 screw

15.0 FITTING THE GLASS FACIA (continued)

Summary of Contents for RADIUM F500080

Page 1: ...ppliance WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIE...

Page 2: ...ional as it may not be operating correctly Section Contents Page No 1 0 General Information 2 2 0 Inventory 2 3 0 Appliance Data 2 4 0 Important Safety Information 2 5 0 Codes 3 6 0 Combustion and Ven...

Page 3: ...ed from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propane or natura...

Page 4: ...s a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distance of 20 of the appliance sides No such materia...

Page 5: ...plate The bottom of the heater may be secured onto the lower mounting studs using the wingnuts or the hex nuts provided Mark the positions shown as Radium attachment points on the wall If the applianc...

Page 6: ...or partially blocked clean out the ports The heater regulator controls the burner pressure which should be checked at the pressure test points located on the control valve itself shown in figure 5 for...

Page 7: ...it strip off the burner pipes and clean thoroughly 8 Clean the in line restrictor pilot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble...

Page 8: ...ons and run at maximum setting for 15 minutes Position gas sample probe directly over a cata lyst via the outlet grille on top of the appliance Record the carbon diox ide CO2 concentration and then th...

Page 9: ...nder section B above If you do not smell gas go to next step 6 The pilot is located on the left side behind the burner Figure 8 7 Depress control knob in and turn counterclockwise to the SPARK positio...

Page 10: ...en fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check m...

Page 11: ...G FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY As our policy is...

Page 12: ...ALACI N AJUSTE MODIFICACI N REVISI N O MANTENIMIENTO INADECUADOS PUEDEN CAUSAR LESIONES O DA OS MATERIALES CONSULTE ESTE MANUAL SI NECESITA AYUDA O INFORMACI N ADICIONAL CONSULTE A UN INSTALADOR CALIF...

Page 13: ...gina N 1 0 Informaci n general 13 2 0 Inventario 13 3 0 Especificaciones del aparato 13 4 0 Informaci n de seguridad importante 13 5 0 Normativa 14 6 0 Aire de combusti n y ventilaci n 14 7 0 Requisit...

Page 14: ...Fuel Gas Code ANSI Z223 1 o NFPA54 que pueden obtenerse en The American National Standards Institute Inc 1430 Broadway New York NY 10018 o National Fire Protection Association Inc Batterymarch Park Qu...

Page 15: ...ier material susceptible de decolorarse derretirse o deformarse al estar expuesto a un calor moderado debe considerarse como material o superficie combustible Debe dejarse un espacio libre de 4 en los...

Page 16: ...er sometida a pruebas de estanqueidad antes de aplicar protecci n y o empotrar las tuber as y acoplamientos Una vez que haya seleccionado la posici n final de montaje del aparato teniendo en cuenta lo...

Page 17: ...be comprobarse en los puntos de prueba de presi n ubicados en la v lvula de control en s ilustrado en la Figura 5 para ajustar la presi n del quemador colector y el regulador La v lvula se encue ntra...

Page 18: ...del quemador desmonte los tubos del quemador y limpie a fondo 8 Limpie el restrictor en l nea el conjunto del piloto y el tubo del quemador No intente retirar el inyector del piloto puesto que podr a...

Page 19: ...te al fabricante del equipo Encienda la chimenea siguiendo las instrucciones de uso y deje que funcione durante 15 minutos Ponga la sonda del analizador de gas directamente encima de un catalizador a...

Page 20: ...n deseada Cierre el panel de acceso a la perilla de control Si la perilla no sale desista y llame inmediatamente a su t cnico de mantenimiento o a su compa a de gas Si despu s de varios intentos el p...

Page 21: ...I DOBLE EL TERMOPAR PARA HACER QUE EL PILOTO SE MANTENGA ENCENDIDO La llama del piloto se reduce cuando Flujo defectuoso de gas al calentador compruebe la presi n con el calentador en Alto el calentad...

Page 22: ...VERTENCIA EL NO UBICAR LAS PIEZAS EN LOS LUGARES SE ALADOS EN ESTOS DIAGRAMAS O LA UTILIZACI N DE PIEZAS NO HOMOLOGADAS OFICIALMENTE PARA EL USO CON ESTE CALENTADOR PUEDEN CAUSAR DA OS MATERIALES O LE...

Reviews: