FIXING TTHE A
APPLIANCE ((continued)
a) FFlat W
Wall LLocation:
There are three fixing positions, two upper “hanging” positions”, and one lower position on the back-panel locat-
ed behind the fuel bed. A template is provided to aid location of fixings. Use a spirit level to ensure that the tem-
plate is level. This ensures that both upper and lower fixing positions are horizontally aligned.
Using the template in the required position on the wall, “mark through” the template and onto the wall at the
three mounting locations designated “P23E” for this particular appliance. Now remove the template.
Wall FFixings:
If the appliance is to be mounted on the inner leaf of a conventional cavity wall or a solid wall, drill three holes
using a 7.0mm masonry bit, to a depth equal to the wall plug, ie 37mm.
Insert the wall-plugs provided and ensure that they are flush with the wall. If the appliance is to be mounted on
a dry lined wall or timber framed construction, then special cavity screw fixings will be required, that are not sup-
plied with this product. Insert 2 x 37mm long fixing screws into the upper two wall-plugs, taking care to leave
the screws protruding approximately 6mm from the wall.
The appliance can now be “hung” onto the two upper wall fixings, ensuring that the heads of the screws go
through the keyhole shaped holes, and then drop down into the slot.
Ensure that the lower rear panel fixing hole aligns with the wall plug, and then insert 1 x 37mm long fixing screw
and fully tighten.
Finally fully tighten the two upper fixing screws, through the two panel acess holes at the front of the appliance.
b) C
Corner W
Wall LLocation:
A fixing template is not provided for corner fixing as the corner fixing
bracket itself may be used for the purposes of marking out. The cor-
ner that the appliance is to be installed into must be square and the
walls must be flat. The corner fixing bracket is supplied pre-assembled.
Position the corner mounting bracket in the desired location, and
using a spirit level, ensure the bracket is square and not twisted.
With the bracket held in position mark the required fixing positions on
the wall. It is recommended that the bracket is fixed to the wall in at
least six positions as shown in figure 5.
Note: Use of the horizontally slotted fixing holes may allow some fine
adjustment before finally tightening the fixing screws.
Drill the wall as appropriate for the type of wall as previously described
in this section, and insert the chosen type of wall fixings and attach the
corner bracket to the walls, using the fixing screws. Before finally tight-
ening the screws, use a spirit level again to check the bracket is square
and not twisted.
With the corner mounting bracket in position, now hang the upper
mounting brackets on the back panel of the appliance onto the two cor-
responding hooks on upper cross section of the corner mounting
bracket (see figure 6).
5
Fig 55
TOP
Upper
mounting
hooks
Lower
screw fixing
Fig 66
©
2007 Focal Point Fires plc.