Model 920 Ethernet Data Multiplexer Manual
Focal Technologies Corporation
Page 5-3
A Moog Inc. Company
920-0603-00 Rev K
Diagnostics
4
Reserved
3
Reserved
2
Reserved
1
Reserved
0
Reserved
40007
15
R
SFP REMOTE Temp High Alarm
Set when internal temperature exceeds high alarm
level.
14
R
SFP REMOTE Temp Low Alarm
Set when internal temperature is below low alarm level.
13
R
SFP REMOTE Vcc High Alarm
Set when internal supply voltage exceeds high alarm
level.
12
R
SFP REMOTE Vcc Low Alarm
Set when internal supply voltage is below low alarm
level.
11
R
SFP REMOTE Tx Bias High
Alarm
Set when TX Bias current exceeds high alarm level.
10
R
SFP REMOTE Tx Bias Low Alarm
Set when TX Bias current is below low alarm level.
9
R
SFP REMOTE Tx Pwr High Alarm
Set when TX output power exceeds high alarm level.
8
R
SFP REMOTE Tx Pwr Low Alarm
Set when TX output power is below low alarm level.
7
R
SFP REMOTE Rx Pwr High
Alarm
Set when Received Power exceeds high alarm level.
6
R
SFP REMOTE Rx Pwr Low Alarm
Set when Received Power is below low alarm level.
5
Reserved
4
Reserved
3
Reserved
2
Reserved
1
Reserved
0
Reserved
40008
15
R
SFP REMOTE Temp High
Warning
Set when internal temperature exceeds high warning
level.
14
R
SFP REMOTE Temp Low
Warning
Set when internal temperature is below low warning
level.
13
R
SFP REMOTE Vcc High Warning
Set when internal supply voltage exceeds high warning
level.
12
R
SFP REMOTE Vcc Low Warning
Set when internal supply voltage is below low warning
level.
11
R
SFP REMOTE Tx Bias High
Warning
Set when TX Bias current exceeds high warning level.
10
R
SFP REMOTE Tx Bias Low
Warning
Set when TX Bias current is below low warning level.
9
R
SFP REMOTE Tx Pwr High
Warning
Set when TX output power exceeds high warning level.
8
R
SFP REMOTE Tx Pwr Low
Warning
Set when TX output power is below low warning level.