background image

V20200828 

• 

Page 3 of 4

Model: F5.0L-PSG, F10.0L-PSG, F5.0L, F10.0L

2

 

Operation

1.

   Remove all components from the packaging.

2

For F5.0L and F10.0L:

 Attach the wand assembly 

(LC-LLA) to the trigger handle (LC-PSG).             

For F5.0L-PSG and F10.0L-PSG:

 Continue to step 3.

3.

  Pull the green pressure release valve (LC-PRV) until 

the red portion of the stem is showing to confirm the 

unit is not pressurized.

4.

  Securely hold the unit and unscrew the pump 

assembly (LC-PA) from the tank head (LC-THA) to 

access the filler hole.

5.

  Follow all instructions from the chemical 

manufacturer when filling the unit. Fill the tank 3/4 full 

with pre-mixed solution. Do not overfill the tank.

6.

  Securely hold the unit and screw the pump assembly 

(LC-PA) into the tank head (LC-THA) to close the unit.

7.

  To pressurize the tank, rotate the handle of the pump 

assembly (LC-PA) until it is free then pump up the 

unit. The pressure relief valve (LC-PRV) will begin 

leaking air when the tank is fully pressurized.

8.

  Once the desired pressure has been achieved, push 

the handle of the pump assembly (LC-PA) down and 

rotate to lock it in place.

9.

  To start foaming, point the wand or trigger gun at 

the area you wish to foam and squeeze the trigger 

handle to discharge foam.

After Use Instructions

1.  

Disconnect the airline from the air fitting. Release air 

pressure from unit after each use by activating the 

pressure relief valve.

2.  

Flush the unit with fresh water. It is recommended to 

always empty out remaining solution and run fresh 

water through the unit to rinse all parts thoroughly 

after each use and before storage.

Maintenance Instructions

To keep your unit operating properly, periodically 

perform the following maintenance procedures:
•  Check the pump assembly (LC-PA) for wear and 

leaks.

•  Check the suction line for debris and clean as 

needed.

•  Periodically lubricate the pump seal with food safe 

lubricant. To lubricate the pump seal, rase the 

handle of the pump assembly (LC-PA) and apply 

5-10 drops of food safe lubricant between the pump 

and pump sleeve.

4

6

2

3

9

5

F5.0L, F10.0L

Summary of Contents for F5.0L-PSG

Page 1: ...t our customer service department Product specifications F5 0L PSG F5 0L F10 0L PSG F10 0L Power type Manual Manual Chemical pickup type Pre mixed solution Pre mixed solution Number of products unit can draw from One product One product Capacity 1 3 gallons 5 liters 2 6 gallons 10 liters Discharge line length diameter 6 5 ft 2 m hose with 1 4 in 6 4 mm inside diameter 6 5 ft 2 m hose with 1 4 in 6...

Page 2: ...g burns serious injury or death DO NOT use a solution with a temperature above 100 F 37 77 C Operating the unit when damaged or leaking may result in exposure to chemical solutions serious injury or death Never use the unit if it is damaged or leaking Never point the discharge wand at yourself another person or any object you do not want covered in chemical Using incoming air pressure exceeding 10...

Page 3: ...leaking air when the tank is fully pressurized 8 Once the desired pressure has been achieved push the handle of the pump assembly LC PA down and rotate to lock it in place 9 To start foaming point the wand or trigger gun at the area you wish to foam and squeeze the trigger handle to discharge foam After Use Instructions 1 Disconnect the airline from the air fitting Release air pressure from unit a...

Page 4: ...ton spray tip for 1 5l 5l LC THA Tank head assembly for 5l 10l includes pressure relief valve and hose retaining nut LC WA OR Oring in 1 5l 5l wand LC WA RN Retaining nut for 1 5l 5l wand assembly LC WD Wadding disk for 1 5l 5l 1 piece PSG12 1 2 In poly spray gun with o ring and gray handle 316SS PUWAND 1 2in mpt poly wand with integrated 65 degree fan tip PWA F100 Wand assembly for F100 TANK10L 1...

Reviews: