WARNING

!

1

 

Safety

PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!

Failure to read all the instructions before operating the unit may result in personal injury or death from 

the improper use of the chemical solution. Anyone handling, operating or using the unit must read, and 

understand, the instructions in the manual. The buyer assumes all responsibility for safety and proper use 

in accordance with the instructions.

Using, or servicing, the unit without proper protective clothing, gloves, and eye 

wear may result in serious injury such as burns, rashes, eye, throat or lung damage 

and death. Always wear protective clothing, gloves, and eye wear when using, or 

servicing, the unit. Protect eyes, skin, and lungs against drifting spray.

Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or 

swallowed. Always read, and follow, all chemical safety precautions and handling instructions provided by 

the chemical manufacturer and the Safety Data Sheet (SDS) associated with the chemical solution being 

used before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and cause 

serious injury such as burns, rashes, eye damage, throat or lung damage and death. Always depressurize 

and clean the unit after each use. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.77°C) may result in scalding, burns, serious injury or 

death. DO NOT use a solution with a temperature above 100°F (37.77°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury 

or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered  

in chemical.
Using incoming air pressure exceeding 100 psi (7 bar) may result in pressure buildup, explosion, serious 

injury or death. DO NOT exceed 100 psi (7 bar) incoming air pressure when operating the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. 

Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause 

it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with 

fresh water for five (5) minutes when switching from an alkaline to an acid or an acid to an alkaline.

Servicing, or modification, of this unit with parts not listed in this manual may cause the unit to operate improperly. 

Do not use unauthorized parts when servicing the unit.
Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an 

air lubricator before the unit.
Moisture in the air lines may damage the pump and diminish the units life. The air must be filtered, clean, dry and 

free of moisture. If needed, install an air dryer before the unit.

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine components, and hazardous fluids in an 

environmentally safe way according to local waste disposal regulations.

NOTICE

Summary of Contents for F5.0L-PSG

Page 1: ...t our customer service department Product specifications F5 0L PSG F5 0L F10 0L PSG F10 0L Power type Manual Manual Chemical pickup type Pre mixed solution Pre mixed solution Number of products unit can draw from One product One product Capacity 1 3 gallons 5 liters 2 6 gallons 10 liters Discharge line length diameter 6 5 ft 2 m hose with 1 4 in 6 4 mm inside diameter 6 5 ft 2 m hose with 1 4 in 6...

Page 2: ...g burns serious injury or death DO NOT use a solution with a temperature above 100 F 37 77 C Operating the unit when damaged or leaking may result in exposure to chemical solutions serious injury or death Never use the unit if it is damaged or leaking Never point the discharge wand at yourself another person or any object you do not want covered in chemical Using incoming air pressure exceeding 10...

Page 3: ...leaking air when the tank is fully pressurized 8 Once the desired pressure has been achieved push the handle of the pump assembly LC PA down and rotate to lock it in place 9 To start foaming point the wand or trigger gun at the area you wish to foam and squeeze the trigger handle to discharge foam After Use Instructions 1 Disconnect the airline from the air fitting Release air pressure from unit a...

Page 4: ...ton spray tip for 1 5l 5l LC THA Tank head assembly for 5l 10l includes pressure relief valve and hose retaining nut LC WA OR Oring in 1 5l 5l wand LC WA RN Retaining nut for 1 5l 5l wand assembly LC WD Wadding disk for 1 5l 5l 1 piece PSG12 1 2 In poly spray gun with o ring and gray handle 316SS PUWAND 1 2in mpt poly wand with integrated 65 degree fan tip PWA F100 Wand assembly for F100 TANK10L 1...

Reviews: