FOAMICO 7009077 Manual Download Page 8

 

 

8 B 540-27-F + feed pump_7009077  US – 07-02-2019 

 

 DANGER 

Electrocution hazard 

Unprofessional work on the electric equipment can result in severe injury 
and death. 

Switch of the power supply, before connecting or removing a plug from electric 
outlets. 

 

 

NOTICE 

Use only original FOAMICO Nozzles, hoses, couplings and spare parts. 

2.2   Precautionary measures  

The construction of the system is in accordance with the generally adopted, technical requirements and the 
stipulations concerning working environment and accident prevention. Therefore the equipment must be in 
its best technical state before being used, and must only be utilized according to its requirements and by 
observance of the precautionary measures and operational instructions. Disturbances, which might influence 
the safety, must be rectified immediately.  

2.3  Appropriate utilization  

FOAMICO low-pressure system is manufactured with the purpose of:  
Rinsing with water, spreading foam and sanitizer within the stated boundaries. 
 
Any other kind of application or use beyond this is considered to be inappropriate and deviant concerning the 
requirements, and may lead to dangerous situations. FOAMICO is not liable for any sequential damages 
brought about by this. 
Appropriate utilization includes the following: 
 
The instructions, regulations, and recommendations given in this manual. 
The observance of the prescribed intervals for inspection and maintenance. 
The correct maintenance for good operational condition of the system. 
The observance of the prescribed conditions for the environment and operation 
 

 

 DANGER 

Risk of chemical burns 

Improper handling of chemicals results in a risk of chemical burns.  

When handling chemicals, ensure that the information provided by the chemical 
supplier is strictly observed. 

The foam is adjusted by means of maximum nozzles, be sure to observe recommendations of the respective 
chemical supplier.  

Summary of Contents for 7009077

Page 1: ...1B 540 27 F feed pump_7009077 US 07 02 2019 Manual FOAMICO Booster Station B 540 27 F Feed pump 7009077...

Page 2: ...cation and Mounting 10 3 3 Water Supply 10 3 4 Electrical Supply 11 4 Operation 12 4 1 Start procedure 12 4 2 Stop procedure 13 5 Troubleshooting 15 5 1 Failures control system 15 5 2 The pump does no...

Page 3: ...ble return from FOAMICO after finished repairs rest with FOAMICO The defect parts are the property of FOAMICO Claims which might be raised for any other legal reason or normal wear and tear as well as...

Page 4: ...the person responsible for this product Should the manual get lost please don t hesitate to require another one from your agent 1 5 Declaration of conformity We FOAMICO declare that this product is i...

Page 5: ...the product or something in its vicinity could be damaged Prevention 2 Safety 2 1 Safety during operation of the system WARNING Burn hazard The operating machine presents a danger of scalding from ho...

Page 6: ...injuries ear damage danger of swallowing loss of stability Directing a jet of water cleaning fluid or liquid disinfectant at persons can lead to eye injury or ear damage swallowing or the loss of sta...

Page 7: ...by the impact from the water jet on the surroundings It is therefore recommended the use ear protectors during the cleaning process NOTICE The hand arm vibration level measured by using a low pressure...

Page 8: ...OAMICO low pressure system is manufactured with the purpose of Rinsing with water spreading foam and sanitizer within the stated boundaries Any other kind of application or use beyond this is consider...

Page 9: ...ructions for Mounting and Installation CAUTION Personal injury and damage to property may result from the installation of damaged parts The installation of damaged parts may cause personal injury and...

Page 10: ...distance from the water supply the maximum water flow and vertical distance from the boosting System 3 3 Water Supply NOTICE Connection to water supply should always be done in according to local or n...

Page 11: ...rk on the electric equipment of the main station can result in severe injury and death The user or the installer is responsible for the installation of correct earthing and protection according to cur...

Page 12: ...illed the pump and other components may be damaged Do not start the main station until the pipe system has been filled with water and vented Do not start the main station until the pump has been fille...

Page 13: ...switch shall always be turn off STOP Turn the On Off switch POS C Fig 4 1 into position Off The booster station is now stopped Read the section on Operating mode in the Grundfos manual Grundfos Hydro...

Page 14: ...7 bar Inlet pressure Actual measured inlet pressure Liquid temp water temperature in top of the pump Figure 4 3 Display photo Pump running Discharge press Stop Actual discharge pressure from pump maxi...

Page 15: ...he water level in the tank is below minimum Fill the tank The ball valve at the inlet of the system is not opened Open the ball valve Unstable rinsing pressure Unoriginal rinsing nozzle with too high...

Page 16: ...ollowing Check for water leakages in the pipe system Check the non return valve Check the flow switch Reset the unit Turn the Switch POS C fig 4 1 into 0 position for 5 seconds Turn the Switch POS C f...

Page 17: ...s Reset the unit Turn the Switch POS C fig 4 1 into 0 position for 5 seconds The unit will start when there is water consumption Follow the instruction at the display to set it back to the home screen...

Page 18: ...security reasons it is recommended to change the hose at least once every 12 months 6 2 Nozzles Nozzles are warned over time And warned out nozzle is less effective It can result in less rinsing powe...

Page 19: ...s own air supply system Failure in the cleaning system could accidentally lead to water and or detergent can flow back in the air system To avoid damage on other installations It is mandatory to make...

Page 20: ...43 3A Fuse A 63 Dimension W x H x D mm 1645 x 1070 x 905 Weight kg 450 All Measurements are average 7 1 Resulting outlet pressure The pump is programmed to deliver the maximum possible outlet pressure...

Page 21: ...21 B 540 27 F feed pump_7009077 US 07 02 2019 8 Spare parts 8 1 Booster B 540 27 F Feed pump All Measurements are average...

Page 22: ...22 B 540 27 F feed pump_7009077 US 07 02 2019 Figure 8 1 Booster...

Page 23: ...23 B 540 27 F feed pump_7009077 US 07 02 2019 Table 8 1 Booster station B540 27 F Feed pump 9 Wiring diagram The electrical diagram is delivered as a separate part of the manuals...

Page 24: ...4 B 540 27 F feed pump_7009077 US 07 02 2019 9 1 Flow Diagram In and outlets A Water inlet A Water inlet Components 2 Ball valve 2 Ball valve 4 Pump 4 Pump 7 Pressure transmitter 7 Pressure transmitte...

Page 25: ...2019 10 Name Plate 1 Company Name 8 Maximum pressure 2 Production date 9 Min Max inlet pressure 3 Serial number 10 Power 4 Item Number 11 Current 5 Model type 12 Voltage 6 Maximum allowed flow 13 Fre...

Page 26: ...F B 050 27 C B 065 27 F B 065 27 C B 100 27 F B 100 27 C B 120 27 F B 120 27 C B 200 27 F B 200 27 C B 270 27 F B 270 27 C B400 F B540 F B630 F B630 F B810 F B1080 F B540 F Feed pump to which this dec...

Reviews: