3 B 540-27-F + feed pump_7009077  US – 07-02-2019 

Introduction

 

FOAMICO congratulates you with your new Booster system. The B 540-27 is developed to connect to 
FOAMICO Cleaning Satellites. The Booster series are developed to be used for professional cleaning 
purpose. The system is manufactured mainly of high grad stainless steel. It is designed to meet today’s high 
hygiene standards. 

 

NOTICE 

To use and operate the system this manual must be read carefully. 

 

Attention! 

 To use and operate the system this manual must be read carefully. 

1.1  Condition of liability 

The responsibility for the treatment and operation in an appropriate manner rests with each individual user. 
Thus it is of great importance that this manual is available to the sanitary employee at any time. 

1.2  Guarantee conditions. 

For a period of 12 months from the date of delivery your dealer warrants for parts which don’t function due 
to defects of material or production. This guarantee does not cover wearing parts (as described in the section 
about spare parts). This guarantee is covering the replacement or repair of the defect part. Any dismounting, 
forwarding, and mounting expenses are paid by the purchaser. The costs for any possible return from 
FOAMICO after finished repairs rest with FOAMICO. The defect parts are the property of FOAMICO 
 
Claims which might be raised for any other legal reason, or normal wear and tear, as well as damage on parts 
which can be related to negligent or wrong treatment, are not covered by this guarantee.  
 
This guarantee does not cover at all, if the system has been exposed to frost.  
 
This guarantee becomes void if changes or repairs have been implemented by non-authorized persons. Any 
claims under the guarantee will only be accepted if they are announced to 
 
FOAMICO immediately after the damage has been observed. This guarantee becomes void as soon as the 
system changes ownership.  
 
Dealers and FOAMICO cannot be held responsible for personal injuries, damages to equipment, loss of 
earning including those caused by production loss, loss of stock or the like, which might arise from 
inappropriate or delayed delivery of the sold product, regardless the reason, including defects in production 
or material. In addition, please read our usual terms of sale and delivery 

 

WARNING 
Due to the nature of low pressure cleaning systems Pressure surges can occur. The installer is responsible for 
dimensioning the supply line to be able to adapt Pressure surge. 
Dealers and FOAMICO cannot be held responsible for personal injuries, damages to equipment surrounding 
rooms, Water Supply line or water outlet line.  
 

Summary of Contents for 7009077

Page 1: ...1B 540 27 F feed pump_7009077 US 07 02 2019 Manual FOAMICO Booster Station B 540 27 F Feed pump 7009077...

Page 2: ...cation and Mounting 10 3 3 Water Supply 10 3 4 Electrical Supply 11 4 Operation 12 4 1 Start procedure 12 4 2 Stop procedure 13 5 Troubleshooting 15 5 1 Failures control system 15 5 2 The pump does no...

Page 3: ...ble return from FOAMICO after finished repairs rest with FOAMICO The defect parts are the property of FOAMICO Claims which might be raised for any other legal reason or normal wear and tear as well as...

Page 4: ...the person responsible for this product Should the manual get lost please don t hesitate to require another one from your agent 1 5 Declaration of conformity We FOAMICO declare that this product is i...

Page 5: ...the product or something in its vicinity could be damaged Prevention 2 Safety 2 1 Safety during operation of the system WARNING Burn hazard The operating machine presents a danger of scalding from ho...

Page 6: ...injuries ear damage danger of swallowing loss of stability Directing a jet of water cleaning fluid or liquid disinfectant at persons can lead to eye injury or ear damage swallowing or the loss of sta...

Page 7: ...by the impact from the water jet on the surroundings It is therefore recommended the use ear protectors during the cleaning process NOTICE The hand arm vibration level measured by using a low pressure...

Page 8: ...OAMICO low pressure system is manufactured with the purpose of Rinsing with water spreading foam and sanitizer within the stated boundaries Any other kind of application or use beyond this is consider...

Page 9: ...ructions for Mounting and Installation CAUTION Personal injury and damage to property may result from the installation of damaged parts The installation of damaged parts may cause personal injury and...

Page 10: ...distance from the water supply the maximum water flow and vertical distance from the boosting System 3 3 Water Supply NOTICE Connection to water supply should always be done in according to local or n...

Page 11: ...rk on the electric equipment of the main station can result in severe injury and death The user or the installer is responsible for the installation of correct earthing and protection according to cur...

Page 12: ...illed the pump and other components may be damaged Do not start the main station until the pipe system has been filled with water and vented Do not start the main station until the pump has been fille...

Page 13: ...switch shall always be turn off STOP Turn the On Off switch POS C Fig 4 1 into position Off The booster station is now stopped Read the section on Operating mode in the Grundfos manual Grundfos Hydro...

Page 14: ...7 bar Inlet pressure Actual measured inlet pressure Liquid temp water temperature in top of the pump Figure 4 3 Display photo Pump running Discharge press Stop Actual discharge pressure from pump maxi...

Page 15: ...he water level in the tank is below minimum Fill the tank The ball valve at the inlet of the system is not opened Open the ball valve Unstable rinsing pressure Unoriginal rinsing nozzle with too high...

Page 16: ...ollowing Check for water leakages in the pipe system Check the non return valve Check the flow switch Reset the unit Turn the Switch POS C fig 4 1 into 0 position for 5 seconds Turn the Switch POS C f...

Page 17: ...s Reset the unit Turn the Switch POS C fig 4 1 into 0 position for 5 seconds The unit will start when there is water consumption Follow the instruction at the display to set it back to the home screen...

Page 18: ...security reasons it is recommended to change the hose at least once every 12 months 6 2 Nozzles Nozzles are warned over time And warned out nozzle is less effective It can result in less rinsing powe...

Page 19: ...s own air supply system Failure in the cleaning system could accidentally lead to water and or detergent can flow back in the air system To avoid damage on other installations It is mandatory to make...

Page 20: ...43 3A Fuse A 63 Dimension W x H x D mm 1645 x 1070 x 905 Weight kg 450 All Measurements are average 7 1 Resulting outlet pressure The pump is programmed to deliver the maximum possible outlet pressure...

Page 21: ...21 B 540 27 F feed pump_7009077 US 07 02 2019 8 Spare parts 8 1 Booster B 540 27 F Feed pump All Measurements are average...

Page 22: ...22 B 540 27 F feed pump_7009077 US 07 02 2019 Figure 8 1 Booster...

Page 23: ...23 B 540 27 F feed pump_7009077 US 07 02 2019 Table 8 1 Booster station B540 27 F Feed pump 9 Wiring diagram The electrical diagram is delivered as a separate part of the manuals...

Page 24: ...4 B 540 27 F feed pump_7009077 US 07 02 2019 9 1 Flow Diagram In and outlets A Water inlet A Water inlet Components 2 Ball valve 2 Ball valve 4 Pump 4 Pump 7 Pressure transmitter 7 Pressure transmitte...

Page 25: ...2019 10 Name Plate 1 Company Name 8 Maximum pressure 2 Production date 9 Min Max inlet pressure 3 Serial number 10 Power 4 Item Number 11 Current 5 Model type 12 Voltage 6 Maximum allowed flow 13 Fre...

Page 26: ...F B 050 27 C B 065 27 F B 065 27 C B 100 27 F B 100 27 C B 120 27 F B 120 27 C B 200 27 F B 200 27 C B 270 27 F B 270 27 C B400 F B540 F B630 F B630 F B810 F B1080 F B540 F Feed pump to which this dec...