11
B 540-27-F + feed pump_7009077
US – 07-02-2019
The water should be connected to the inlet shown in
POS A
. fig. 4.1
CAUTION
Property damage
If the pump runs dry it may be damaged.
The pump must be filled with water and vented. Open the vent valve
POS. D
fig. 4.1, until all air is out of the pump.
After venting the Feed pump, the green push button (
pre-boost)
can be used
to pressurize the two Booster pumps.
AFTER mounting the system flushing of the pipes must always be done with the system in “rinsing mode”,
in order to avoid any impurities in the injector system. Please keep rinsing until the rinsing nozzle shows an
invariable clean water jet coming out.
3.4 Electrical Supply
DANGER
Elektric shock, electrocution
Unprofessional work on the electric equipment of the main station can
result in severe injury and death.
The user or the installer is responsible for the installation of correct earthing and
protection according to current national and local standards. All operations must
be carried out by qualified personnel.
Connection to the power supply must only been made by authorised
electrician’s´. The connection has to be done to a main switch installed next to
the station. Always consult the pump manual before making the connections.
DANGER
Elektric shock, electrocution
Any work being carried out on the electric parts of the pump without it
having been disconnected from the electrical supply can lead to severe
injury and death.
Never make any connections in the pump terminal box unless electric supply
circuits have been switched off for at least 5 minutes.
CAUTION
Connection the power supply must only been made by authorised
electrician’s´.