IGNITION SYSTEM ENABLED BY THE REMOTE CONTROL
LEVER IN IDLING POSITION
The purpose is that of making sure that the start of the engine only takes place when the remote control
lever is placed in the idling position.
The operations that need to be done are as following:
1.
when looking at the ignition key from behind, figure 1, proceed to disconnecting the female fast-on
from the pin “
50a
” as indicated by the arrow;
2.
connect the two electric cables (yellow/red) of the remote control lever circuit, respectively the male
with the female that had been previously disconnected from the ignition key (red) and the female
fast-on in the ignition key block (see figure 2).