background image

The locking IC seat is divided into 

1-2-3 area

 and 

K-A-A area

 (as shown above)

The locking IC seat has a total of 14 jacks.Each jack is marked 1, 2, 3, K, A.If the 

labels are the same, they are connected internally and have the same function

Note: In DSO oscilloscope mode, the parameters will be automatically

            saved if there is no key operation for 0.5 seconds

Button

Function Description

Digital Oscilloscope

OFF

Auto-adjustment rate below 20Hz

cannot be calibrated correctly

Transistor Tester

Enter or exit

the system

Confirm current

operation

Move/change

mode

Start a new

measurement

Enter the calibration confirmation

interface - press the OK button to enter

the calibration mode(long press AUTO

again to cancel the calibration)
Select the operation object
Fast-moving
Move up/change mode
Move up continuously

Move down/Change mode
Move down continuously

Operate

Long Press

Short Press

Long Press

Short Press

Long Press

Short Press

Long Press

Short Press

Long Press

Short Press

Long Press

Short Press

Pause/Start Waveform
In the vertical voltage gear position, 

long press to switch X1/X10.

In other cases, long press to show/

close detailed parameters

Test mode selection

【 Ocking IC Seat 】

1-2-3 area

K-A-A area

Locking lever

【4.2】  Transistor Test Socket

��

PAGE

Summary of Contents for DSO-TC2

Page 1: ...Oscilloscope Transistor Tester DSO TC2...

Page 2: ......

Page 3: ...tton function 04 4 2 Transistor test socket 05 4 3 Signal interface 06 4 4 Charging interface 07 4 Button Interface 5 Oscilloscope Mode Features 5 1 TFT display 07 5 3 Oscilloscope probe 08 5 2 Real t...

Page 4: ...and wordless components and preliminary screening of small batch components Mode Display PAGE Please read the manual carefully before use Do not use the instrument in a ammable and explosive environme...

Page 5: ...ycle 3 1 FNIRSI DSO TC2 Equipment Parameters 3 2 Speci cations Of Oscilloscope Mode Display Powered by Charging Size Bracket 2 4 inch TFT color screen LED backlight 1500mAh rechargeable lithium batter...

Page 6: ...omatic measurement PWM output Rising edge falling edge Adjustable with indication Yes HOLD function Maximum minimum average rms peak to peak frequency period duty cycle FRQ 0 80KHz Duty cycle 0 100 Am...

Page 7: ...DHT1 PWM output Infrared remote control decoding Note Ices Iceo Uf are displayed only when valid Note Junction capacitance and reverse leakage current are displayed only when valid Note The turn on or...

Page 8: ...rrent operation Move change mode Start a new measurement Enter the calibration con rmation interface press the OK button to enter the calibration mode long press AUTO again to cancel the calibration S...

Page 9: ...ge inside K is positive and A is negative It is used for withstand voltage test and cannot be mixed The positive electrode of the component under test such as the Zener diode is inserted into A and th...

Page 10: ...tic triggering Single means a single trigger Normal means normal trigger Baseline indicator icon This icon indicates the position that the current position is OV voltage Trigger voltage indicator icon...

Page 11: ...imum voltage Vave Average Voltage Vrms RMS voltage Vpp Peak to Peak Voltage Fre Frequency Dut Positive duty cycle Cyc Cycle 5 2 Real time Measurement Parameters 5 3 Oscilloscope Probe NOTE Note When t...

Page 12: ...or turn o voltage of the FET should be less than 5V Other wise the measured results are only its equivalent parameters diodes capacitors etc 6 1 Operation And TFT Display 6 2 Zone 1 2 3 Test Seat PAGE...

Page 13: ...as double diodes At the same time the LED will ash 6 3 Zone K A A Test Seat 6 4 Infrared Remote Control Decoding Note This instrument only supports infrared code decoding of NEC protocol PAGE Insert t...

Page 14: ...U button to enter the setting menu Press TEST button again to enter the function page Extended test items and calibration function items are provided here PAGE 1 Boot LOGO O On 2 System language Engli...

Page 15: ...age the device NOTE 3 PWM Output adjustable frequency and duty cycle output from the top MCX jack PWM 4 Zener Diode Use the test seat K A A area for testing See description in 6 3 5 DS18B20 Follow the...

Page 16: ...OMMON PROBLEM A When the battery is fully charged the charging indicator will change from red to green 2 Why does the tested waveform keep shaking left and right and cannot be xed 1 How to judge wheth...

Page 17: ...cable Press AUTO button to enter the calibration con rmation interface Then click the OK button to enter the automatic calibration 5 Why is there no signal input The baseline OV on the screen and the...

Page 18: ...o strong vibrations 5 Do not place the machine in places with high humidity dust direct sunlight outdoors or near heat sources 6 USB rmware upgrade only supports WIN10 and above Drag in les other than...

Page 19: ......

Page 20: ...w w w f n i r s i c n...