FMUSER INTERNATIONAL GROUP INC.
广州市汉婷生物技术开发有限公司
10
/
36
3.2 General setting
By pressing “LOCK” key to enter the main menu, the LCD will display the following pages:
1 Alarm Status 2 System Setting
3 Output Setting 4 Network Setting
5 Saving Config 6 Loading Config
7 Version
By pressing UP or DOWN key to the specified menu item, and then pressing ENTER, users can
enter the submenu as following pages:
3.2.1 Alarm Status
Current TS Rate: 38.01 Mbps
Alarm Count: 0
Ø
Current TS Rate
The figure displayed in the first row shows the real-time TS bit rate.
Ø
Alarm count
The Alarm count in the second row indicates the amount of the errors. Whenever an abnormal event
happens, the number will increase 1.
If the alarm count is not equal to 0, it must be at least one error happening. User can press ENTER
key to enter the submenu to check the alarm details. These alarms include the following events:
1.
Clock Lose:
When the outer 10MHz reference clock is chosen as modulator’s working
clock, the modulator cannot detect reference clock input.
2.
No Input TS:
No TS input or TS is cut off
3.
Input TS Overflow:
Input TS bit rate overflow the bandwidth of Transmission Limit
4.
Internal Error:
Internal error of the modulator