background image

                                          FMUSER INTERNATIONAL GROUP INC.         

广州市汉婷生物技术开发有限公司

 

 

27

 / 

36

 

 

modulator. The possible FEC rates include 1/4, 1/3, 2/5, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 when 

the constellation is QPSK, and 3/5, 2/3, 3/4, 5/6, 8/9, 9/10 when the constellation is 8PSK. 

Ø

 

Pilot Insert 

User can choose whether to insert the Pilot in the check box.

 

Ø

 

Symbol Rate 

 

  Range: DVB-S: 0.5~45M; DVB-S2: 0.5~30M 

Ø

 

RF Output Frequency 

 

User  can  set  RF  output  frequency.  The  RF  output  frequency 

range is from 950 to 2150MHz. 

Ø

 

RF Output Mode 

 

User can set the RF output mode for different applications.   

Single Tone:

 the RF output is only carrier without modulation.   

Modulation:

 The RF output carrier with modulation.   

Off:

 Turn off the RF output. 

Ø

 

RF ATT Level 

User can set the attenuation of the RF output. The RF attenuation range is from -10.0 to -41.5db in 

0.5db step.   

Ø

 

Input IP/Port 

 

User can set the input IP address and Port Number in these fields. 

Ø

 

Spectrum Invert 

: User can set the Spectrum mode by checking the checkbox. When selected, it is 

inverted and it is normal if unchecked. 

 

Summary of Contents for FUTV4502D

Page 1: ...FMUSER INTERNATIONAL GROUP INC FUTV4502D DVB S2 Modulator User s Manual NMS Version 5 5 16 SW 1 22 HW 4 0 FMUSER International Group Inc...

Page 2: ...STALLATION GUIDE 5 2 1 ACQUISITION CHECK 5 2 2 INSTALLATION PREPARATION 5 2 3 WIRE S CONNECTION 7 2 4 SIGNAL CABLE CONNECTION 8 CHAPTER 3 OPERATION 9 3 1 MAIN INTERFACE 9 3 2 GENERAL SETTING 10 CHAPTE...

Page 3: ...output This DVB S2 modulator supports local and remote control through NMS software The FUTV4502D DVB S2 modulator with BISS can be used for broadcasting interactive services news gathering and other...

Page 4: ...1 5 dBm 0 5dB Stepping MER 32dB Connector N type impedance 50 Channel Coding and Modulation DVB S DVB S2 Outer coding RS Coding BCH Coding Inner coding Convolutional LDPC Coding FEC Convolution Rate 1...

Page 5: ...FMUSER INTERNATIONAL GROUP INC 3 36 1 5 Appearance and Description Front Panel Illustration Indicator area All the indicators will light on when DVB S2 modulator works at current mode...

Page 6: ...r Panel Illustration 1 RF Output Interface 2 ASI1Input channel 1 4 3 Data Port 4 Network Management System Interface 5 Input of 10Mhz Reference Clock 6 Loop out of 10Mhz Internal Clock 7 Power Switch...

Page 7: ...evice please follow the below steps The details of installation will be described at the rest part of this chapter Users can also refer rear panel chart during the installation The main content of thi...

Page 8: ...sealing door gaps and dual level glasses for window Wall It can be covered with wallpaper or brightness less paint Fire Protection Fire alarm system and extinguisher Power Requiring device power air...

Page 9: ...evice s grounding rod to frame s grounding pole with copper wire 2 3 Wire s Connection The grounding wire conductive screw is located at the right end of rear panel and the power switch fuse power sup...

Page 10: ...cable illustration 2 4 2 RF output interface connection User can firstly find the RF out interface on the device according to the connector mark described on the rear panel illustration and then conne...

Page 11: ...modification MENU Canceling presently entered value resuming previous setting Return to previous menu LOCK Lock the screen cancel the lock state After pressing lock key the system will question the us...

Page 12: ...row shows the real time TS bit rate Alarm count The Alarm count in the second row indicates the amount of the errors Whenever an abnormal event happens the number will increase 1 If the alarm count i...

Page 13: ...pages 2 1 Modulate Mode 2 2 REF Clock Sel 2 3 Input Select 2 4 IP Input Set 2 5 Symbol Rate 2 6 Roll Off 2 7 FEC Rate 2 8 Constellation 2 9 Pilot Insert 2 10 Biss Setting 3 2 2 1 Modulation State 2 1...

Page 14: ...lect the external 10MHz input if it exists Otherwise the modulator will select the internal 10MHz crystal oscillator s output as reference clock 3 2 2 3 Input select 2 3 Input Select ASI 1 2 3 Input S...

Page 15: ...t the roll off factor of the DVB S and DVB S2 There are 3 possible options including 0 35 0 25 and 0 20 3 2 2 7 FEC Rate Convolutional Code Rate 2 7 FEC Rate 9 10 2 7 Conv Code Rate 1 1 3 5 2 3 3 4 5...

Page 16: ...ulator works as DVB S2 modulator The possible FEC rates include 3 5 2 3 3 4 5 6 8 9 9 10 when the constellation is 8PSK 3 2 2 8 Constellation This menu only shows when MODUALTO STATE is DVB S2 2 8 Con...

Page 17: ...B C D E and F at submenu 2 10 3 2 10 1 Biss Mode 2 10 2 Input Port 03 2 10 3 SW Data 01 GXTV 02 Guangdong 9 03 SZTV 01 GXTX No Yes 2 10 3 SW Data 0 X000000000000 When the modulator works under Mode E...

Page 18: ...ncy Setting After entering the submenu by pressing ENTER key user can set RF output frequency The RF output frequency range is from 950 to 2150MHz 3 1 RF Frequency 100 0 00MHz 3 2 3 2 RF Level ATT Set...

Page 19: ...Output 3 4 RF Output single tone 3 4 RF Output 1 1 single tone modulation off User can set the RF output mode for different applications Single Tone the RF output is only carrier without modulation M...

Page 20: ...item Enter and Left Right to set the parameters The system displays following pages 4 1 IP Address 4 2 Subnet Mask 4 3 Gateway 4 4 Console Address 4 5 MAC Address Note The MAC address is according to...

Page 21: ...ressing ENTER key The system displays following page Saving please wait erasing 3 2 6 Load Configuration At this menu press UP DWON key and ENTER to confirm 6 1 Load Saved CFG 6 2 Load Default CFG Use...

Page 22: ...n or place different versions of network management software to the same directory When the network management software is running it will generate two documents as follows l Network management softwa...

Page 23: ...te a device node tree in the left column by adding modifying and deleting the device node This software provides a powerful node operation function and the user can edit various parameters in the devi...

Page 24: ...ouse key to pop up the short cut menu in device tree or in the left blank column then the corresponding dialog box will pop up by choosing Add Main Freq Point The device will confirm the given frequen...

Page 25: ...92 168 0 136 also you can check its IP address in the front panel of device in case the IP changed unexpected 2 The PC IP address and device IP address should be in the same network For example the De...

Page 26: ...the loaded values by clicking Alternatively user can also click the button on the toolbar to popup the save file dialog box which gives prompts to save all the device s parameters as binary files in t...

Page 27: ...S software 4 3 1 General Parameters Setting Modulation Mode User can select the modulator s working mode and relevant constellation at this drop down list DVB S This modulator works as DVB S modulator...

Page 28: ...e clock Input Select ASI1 2 3 4 The input TS comes from port ASI1or 2 or 3 or 4 IP IN The input signal comes from data port Roll off Factor User can set the roll off factor of the DVB S and DVB S2 The...

Page 29: ...RF output frequency range is from 950 to 2150MHz RF Output Mode User can set the RF output mode for different applications Single Tone the RF output is only carrier without modulation Modulation The R...

Page 30: ...re are 3 scramble modes Mode 0 Mode 1 and Mode E Mode 0 Under Mode 0 it does not require to fill any data Mode 1 Under Mode 1 the BISS scrambler applies scrambling through a fixed Control Word CW deri...

Page 31: ...inputting the scrambler key users should press Set to initial scrambling A few seconds later the programs will be scrambled Mode E Under Mode E the BISS scrambler completes scrambling through ESW Dat...

Page 32: ...Remote Save In many cases during the configuration of parameters in NMS users save the modified configuration by clicking Set in which way the configuration can only be saved temporarily and will rest...

Page 33: ...w which signifies the equipment has disconnected Users then can refer to below prompts to edit the property by inputting the new IP to re connect the equipment After finishing all the parameters setti...

Page 34: ...sswords as needed User clicking Setting in the menu bar and selecting User Setting in the pull down list the below dialog box will pop out as shown below Select the Edit Information by marking the che...

Page 35: ...ng sure good ventilation for the heat sink on the rear panel and other heat sink bores if necessary l Checking the input AC voltage within the power supply working range and the connection is correct...

Page 36: ...FMUSER INTERNATIONAL GROUP INC 34 36 Chapter 6 Packing List l FUTV4502D DVB S2 modulator 1pcs l User s manual 1pcs l Power cord 1pcs l ASI wire 4pcs...

Reviews: