Users should make sure the 2 ends of grounding wire well electric conducted
and be antirust.
l
It is prohibited to use any other device as part of grounding electric circuit
l
The area of the conduction between grounding wire and device’s frame should
be no less than 25mm
2
.
2.2.4 Frame Grounding
All the machine frames should be connected with protective copper strip. The
grounding wire should be as short as possible and avoid circling. The area of the
conduction between grounding wire and grounding strip should be no less than
25mm
2
.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and
the power switch, fuse, power supply socket is just beside ,whose order goes like
this, power switch is on the left ,power supply socket is on the right and the fuse is
just between them.
l
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to
AC power.
l
Connecting Grounding Wire
When the device solely connects to protective ground, it should adopt
independent way, say, share the same ground with other devices. When the
device adopts united way, the grounding resistance should be smaller than 1Ω.
F
Caution:
Before connecting power cord to FUTV4314A 4 in 1 MPEG-4 AVC/H.264 HD