 Operating instructions for DIESELFIxx / DIESELMAxx

5.    Servicing

5.1   Replacing worn blades

Danger!
Never work on a pump that is running!

Assemble or disassemble accessories only with switched off pump.

For your own safety additionally isolate the pump unit from the power supply.

Remove cover as in chapter 3.1.

Place a suitable collecting bowl into the housing. During the disassembly small quantities of Diesel can 
leak out.

Open swage fitting between pump and meter and remove meter.

Loosen pump nuts and remove the pump.

Caution!
Spilled fuel can result in environmental damage

Local and country rules and regulations relating to domestic water supplies and fuel 

storage must be obeyed.

Figure 5-1: Pump unit rear view (illustration shows no. 23 420)

Remove worn blades as in the operation manual of the Diesel pump 60 l/min resp. 100 l/min.

Replace in reverse order.

Summary of Contents for DIESELFI Series

Page 1: ...84 882 A801 GB DIESELFIxx DIESELMAxx with NUMERIxx3 oval gear meter mechanical 60 l min 100 l min 230 V 1 AC ...

Page 2: ...orn blades 5 1 _________________________________________________________________8 Repairs Service 6 _______________________________________________________________________9 Spare parts and accessories 7 _____________________________________________________________9 EC Declaration of Conformity 8 _ __________________________________________________________9 Exploded view 9 _ _______________________...

Page 3: ...e stated requirements at the installation 2 General Safety Advice 2 1 Information on safety at work The diesel pump has been designed and manufactured according to the health and safety requirements of the relevant EC guidelines Nevertheless there can still be risks if the product is not set up or operated as stipulated Therefore before using the diesel pump read these operation instructions and p...

Page 4: ...es must be replaced immediately With reference to the period of use please note the details in ZH 1 A45 4 2 or DIN 20066 Part 5 3 2 Caution Spilled fuel can result in environmental damage Local and country rules and regulations relating to domestic water supplies and fuel storage must be obeyed Caution If the diesel pump is incorrectly installed or used for a purpose other than that originally int...

Page 5: ... pressure hose and hang them in the pistol holder on the front panel Caution Nozzle valve must be hung up in order to prevent inadvertent starting of the pump when connecting to the power supply Connect the pump to a 230 V supply through the power connector Lift the nozzle valve briefly from the holder to check if the pump starts up Actuate the rocker switch on the pump if the pump does not start ...

Page 6: ... protection system that the end of the hose is not immersed in the fluid If it is the siphon protection system will not work 4 Operation Check the diesel pump and installed accessories for completeness and damage Replace any damaged components immediately Never use a pump if damaged Check the suction filter for damage each time the tank is filled emptied and replace it if damaged Never operate the...

Page 7: ...mp then operates in the bypass mode Ensure that under no circumstance the pump runs in this mode longer than 2 minutes Switch the pump off after re fuelling as soon as possible This is done by hanging up the nozzle valve into the pistol holder Caution Danger of product damage The power source must be the correct voltage for the pump type For operation of the oval gear meter NUMERIxx3 please refer ...

Page 8: ...llecting bowl into the housing During the disassembly small quantities of Diesel can leak out Open swage fitting between pump and meter and remove meter Loosen pump nuts and remove the pump Caution Spilled fuel can result in environmental damage Local and country rules and regulations relating to domestic water supplies and fuel storage must be obeyed Figure 5 1 Pump unit rear view illustration sh...

Page 9: ... l min No 23 176 resp 23 178 8 EC Declaration of Conformity We hereby declare that the product described here its concept and construction including this particular model complies with the EC requirements Any change to the product not approved by us will invalidate the declaration Product Description DIESELFIxx Product Type Pump unit for diesel Year of Manufacture see nameplate Applicable EC Direc...

Page 10: ... 17 1 Drum Adapter G 2 a G 1 a Alu 19 524 19 524 18 4 Shim DIN 9021 galvanized steel 6 4x18x1 6 87 126 87 126 19 4 Spacer SW13 L22 83 811 83 811 20 1 Diesel pump 60 l min 230 V 1 AC 50 Hz EUS blank 23 100 091 20 1 Diesel pump 100 l min 230 V 1 AC 50 Hz EUS blank 23 102 091 21 4 Washer DIN 433 15x8 4x1 6 zn 88 315 88 315 22 1 Manual for NUMERIxx oval gear meter mechanical 82 550 82 550 23 1 Threade...

Page 11: ...76 45 1 Nozzle valve G 1 i 100 l min Alu 23 178 46 1 Instructions Diesel pump 60 l min on CD 89 349 46 1 Instructions Diesel pump 100 l min on CD 89 351 47 1 Manual for DIESELFIxx DIESELMAxx with NUMERIxx mechanical 84 882 84 882 48 1 Threaded nozzle M5 x 4 GTS 54 MSV 89 278 89 278 49 1 Seal 7 76x5 4x1 PVC 89 279 89 279 50 3 LDPE hose 6x1 mm black 80 327 80 327 51 2 Thermal label H 90 B 165 mm neu...

Page 12: ...12 G Operating instructions for DIESELFIxx DIESELMAxx Figure 9 1 Exploded view of the pump unit DIESELFIxx DIESELMAxx H 25 ...

Page 13: ...13 Operating instructions for DIESELFIxx DIESELMAxx G ...

Page 14: ...FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestraße 6 6330 Cham Schweiz Tel 41 41 712 05 37 Fax 41 41 720 26 21 info fmtag com www fmtag com ...

Reviews: