![FMT DIESELFI Series Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/fmt/dieselfi-series/dieselfi-series_operating-instructions-manual_2313156006.webp)
6
G
Operating instructions for DIESELFIxx / DIESELMAxx
3.2 Mounting the hose support
The hose support is pre-assembled.
Loosen the two screws and pull out the hose support, appr. 100 mm.
Tighten the screws.
Figure 3-2: Mounting the hose support
3.3 Installing the Siphon Protection
Remove cover as in chapter 3.1.
Install the siphon protection according to the manual of the Diesel pump 60 l/min resp. 100 l/min.
Re-assemble the cover in reverse sequence.
Tip
Ensure when installing the siphon protection system that the end of the hose is not immersed
in the fluid. If it is, the siphon protection system will not work!
4. Operation
Check the diesel pump and installed accessories for completeness and damage. Replace any damaged
components immediately. Never use a pump if damaged.
Check the suction filter for damage each time the tank is filled/emptied and replace it if damaged.
Never operate the pump without the suction filter, because the pump will not be protected against
contamination by foreign bodies.
Tip
To ensure that the tank can be completely emptied, the suction hose must reach to the bottom
of the tank.
Position the nozzle valve in the container to be filled.
100 mm