FMT DIESELFI Series Operating Instructions Manual Download Page 2

2

G

 Operating instructions for DIESELFIxx / DIESELMAxx

Contents

General Information

1. 

 __________________________________________________________________2

Usage Stipulations

1.1. 

 ___________________________________________________________________2

Construction and Functional Description

1.2. 

 _________________________________________________2

Application Range

1.3. 

  ___________________________________________________________________3

Operational Area Requirements

1.4. 

  ________________________________________________________3

General Safety Advice

2. 

  ________________________________________________________________3

Information on safety at work

2.1. 

 __________________________________________________________3

Signs and symbols used in the safety instructions

2.2. 

 __________________________________________3

Risks when Working with the Diesel Pump

2.3. 

 ________________________________________________4

Installation

3. 

  _________________________________________________________________________4

Wall mounting

3.1. 

  ______________________________________________________________________4

Mounting the hose support

3.2. 

 ____________________________________________________________6

Installing the Siphon Protection

3.3. 

  ________________________________________________________6

Operation

4. 

 __________________________________________________________________________6

Safety

4.1. 

  _____________________________________________________________________________7

Servicing

5. 

 ___________________________________________________________________________8

Replacing worn blades

5.1. 

 ________________________________________________________________8

Repairs/Service

6. 

 ______________________________________________________________________9

Spare parts and accessories

7. 

 ____________________________________________________________9

EC Declaration of Conformity

8. 

  __________________________________________________________9

Exploded view

9. 

  _____________________________________________________________________10

1.    General Information

1.1   Usage Stipulations

The diesel pump is to be used only for the delivery of diesel fuel. 

Danger!
Never use it to deliver explosive fluids like petrol, or other fluids with similar flashpoints!

The diesel pump must be connected to a 230 V electrical supply.
To ensure that usage stipulations are met, read through the operating instructions completely before 

using the pump and observe all stipulations. 
Any departure from the usage stipulations (other fluid media, use of force) or user modifications 

(changes, use of non-original parts) can be dangerous and are considered as non-stipulated usage. 
The user is liable for any damage resulting from non-stipulated use.
For any repairs to electrical components, the appropriate safety and test requirements are to be 

observed.
Only original replacement parts are to be used for any repairs, otherwise the warranty will be 

invalidated.

1.2   Construction and Functional Description

The diesel pump can be fitted with a variety of FMT accessories.
To prevent environmental damage the diesel pump is fitted with a siphon protection system. This 

means that if the discharge hose is damaged while the pump is stopped, siphon action will not empty 

the tank.
The fuelling station provides automatic shut down of the pump when the automatic nozzle valve is 

replaced in the holder.

Summary of Contents for DIESELFI Series

Page 1: ...84 882 A801 GB DIESELFIxx DIESELMAxx with NUMERIxx3 oval gear meter mechanical 60 l min 100 l min 230 V 1 AC ...

Page 2: ...orn blades 5 1 _________________________________________________________________8 Repairs Service 6 _______________________________________________________________________9 Spare parts and accessories 7 _____________________________________________________________9 EC Declaration of Conformity 8 _ __________________________________________________________9 Exploded view 9 _ _______________________...

Page 3: ...e stated requirements at the installation 2 General Safety Advice 2 1 Information on safety at work The diesel pump has been designed and manufactured according to the health and safety requirements of the relevant EC guidelines Nevertheless there can still be risks if the product is not set up or operated as stipulated Therefore before using the diesel pump read these operation instructions and p...

Page 4: ...es must be replaced immediately With reference to the period of use please note the details in ZH 1 A45 4 2 or DIN 20066 Part 5 3 2 Caution Spilled fuel can result in environmental damage Local and country rules and regulations relating to domestic water supplies and fuel storage must be obeyed Caution If the diesel pump is incorrectly installed or used for a purpose other than that originally int...

Page 5: ... pressure hose and hang them in the pistol holder on the front panel Caution Nozzle valve must be hung up in order to prevent inadvertent starting of the pump when connecting to the power supply Connect the pump to a 230 V supply through the power connector Lift the nozzle valve briefly from the holder to check if the pump starts up Actuate the rocker switch on the pump if the pump does not start ...

Page 6: ... protection system that the end of the hose is not immersed in the fluid If it is the siphon protection system will not work 4 Operation Check the diesel pump and installed accessories for completeness and damage Replace any damaged components immediately Never use a pump if damaged Check the suction filter for damage each time the tank is filled emptied and replace it if damaged Never operate the...

Page 7: ...mp then operates in the bypass mode Ensure that under no circumstance the pump runs in this mode longer than 2 minutes Switch the pump off after re fuelling as soon as possible This is done by hanging up the nozzle valve into the pistol holder Caution Danger of product damage The power source must be the correct voltage for the pump type For operation of the oval gear meter NUMERIxx3 please refer ...

Page 8: ...llecting bowl into the housing During the disassembly small quantities of Diesel can leak out Open swage fitting between pump and meter and remove meter Loosen pump nuts and remove the pump Caution Spilled fuel can result in environmental damage Local and country rules and regulations relating to domestic water supplies and fuel storage must be obeyed Figure 5 1 Pump unit rear view illustration sh...

Page 9: ... l min No 23 176 resp 23 178 8 EC Declaration of Conformity We hereby declare that the product described here its concept and construction including this particular model complies with the EC requirements Any change to the product not approved by us will invalidate the declaration Product Description DIESELFIxx Product Type Pump unit for diesel Year of Manufacture see nameplate Applicable EC Direc...

Page 10: ... 17 1 Drum Adapter G 2 a G 1 a Alu 19 524 19 524 18 4 Shim DIN 9021 galvanized steel 6 4x18x1 6 87 126 87 126 19 4 Spacer SW13 L22 83 811 83 811 20 1 Diesel pump 60 l min 230 V 1 AC 50 Hz EUS blank 23 100 091 20 1 Diesel pump 100 l min 230 V 1 AC 50 Hz EUS blank 23 102 091 21 4 Washer DIN 433 15x8 4x1 6 zn 88 315 88 315 22 1 Manual for NUMERIxx oval gear meter mechanical 82 550 82 550 23 1 Threade...

Page 11: ...76 45 1 Nozzle valve G 1 i 100 l min Alu 23 178 46 1 Instructions Diesel pump 60 l min on CD 89 349 46 1 Instructions Diesel pump 100 l min on CD 89 351 47 1 Manual for DIESELFIxx DIESELMAxx with NUMERIxx mechanical 84 882 84 882 48 1 Threaded nozzle M5 x 4 GTS 54 MSV 89 278 89 278 49 1 Seal 7 76x5 4x1 PVC 89 279 89 279 50 3 LDPE hose 6x1 mm black 80 327 80 327 51 2 Thermal label H 90 B 165 mm neu...

Page 12: ...12 G Operating instructions for DIESELFIxx DIESELMAxx Figure 9 1 Exploded view of the pump unit DIESELFIxx DIESELMAxx H 25 ...

Page 13: ...13 Operating instructions for DIESELFIxx DIESELMAxx G ...

Page 14: ...FMT Swiss AG Fluid Management Technologies Swiss AG Gewerbestraße 6 6330 Cham Schweiz Tel 41 41 712 05 37 Fax 41 41 720 26 21 info fmtag com www fmtag com ...

Reviews: