4
G
Operating instructions for DIESELFIxx / DIESELMAxx
2.3 Risks when Working with the Diesel Pump
Danger!
Never work on a pump that is running!
Mount or remove attachments and accessories only when the pump is switched off.
■
■
For your own safety, disconnect the pump from the power supply.
■
■
Danger!
Do not pump contaminated fluids!
Take special care to ensure that there is no contaminant in the fluid to be pumped.
■
■
Install a strainer on the suction pipe.
■
■
Danger!
Damaged attachments and accessories can lead to personal injury and material damage!
Suction and pressure pipes must not be kinked, twisted or stretched.
■
■
Attachments and accessories must be checked for wear, splits or other damage at all times.
■
■
Damaged attachments and accessories must be replaced immediately.
■
■
With reference to the period of use, please note the details in ZH 1/A45.4.2 or DIN 20066
■
■
Part 5.3.2.
Caution!
Spilled fuel can result in environmental damage!
Local and country rules and regulations relating to domestic water supplies and fuel
■
■
storage must be obeyed.
Caution!
If the diesel pump is incorrectly installed, or used for a purpose other than that originally
■
■
intended for, it can result in personal injury or damage to equipment!
Before starting to use the diesel pump, read through these operating instructions carefully and
completely.
3. Installation
3.1 Wall mounting
When installing the pump, ensure that it is mounted on a stable surface. Select a secure location
(protected from water spray, damage and theft).
Loosen screw (Item 36) and remove reset wheel (Item 34, 35).
Remove the adaptor (Item 42) on the pressure side.
Loosen the screws on both side walls. The cover can now be removed (see Fig. 3-1).