Operating Instructions 

PREMA

xx

 

 Electrical Pump

 

 

 

Assembly of PREMA

xx

 electrical pump 

1. 

Push the transparent suction hose (6) onto the suction pipe with filter (8). 

2. 

Push the hose clamp (7) over the suction hose (6) to the suction pipe (8) and tighten the 
hose clamp with a screwdriver. 

  

    

 

 

Note 

Before continuing with the next Step, please note: 

If the pump is mounted on the fuel container, the suction hose with the suction pipe must be 
long enough to reach the fuel in the tank even if the fuel level is low. 

 

 

3. 

Cut the suction hose (6) to the desired length. 

4. 

Push the hose clamp (5) over the suction hose (6). 

5. 

Push the suction hose (6) onto the vacuum union (4) on the pump. 

6. 

Push the hose clamp (5) to the vacuum union (4) and tighten the hose clamp with a 
screwdriver. 

 

    

 

Danger!

 

Hoses with insufficient resistance can cause explosions 

In order for the fuel to be delivered without risk, the delivery hose must have a certain 
resistance in order to avoid static charge. The original delivery hose from FMT has the 
necessary resistance. 

 

Use only FMT delivery hose. 

 

When using delivery hoses by other manufacturers make sure that the delivery hose has a 
resistance of > 10

11

 Ohm. 

 

  

 

 

Caution!

 

Risk of product damage 

 

Mount and operate the pump only vertically on a fuel container. 

 

7. 

Firmly screw the pump into the aperture of the fuel tank using the barrel screw joint (3).  
The pump run-off can be brought into any position in the screwed-in state by twisting the 
pump housing (1). 

8. 

Screw the union nut (14) of the black delivery hose onto the pressure union (13) of the 
pump. 

9. 

Screw in the free end of the delivery hose with the external thread (16) into the thread of 
the nozzle (11 or 20 respectively). 

  

    

 

 

Caution!

 

Risk of product damage 

 

The power source must have the correct voltage for the pump type. 

 

10. 

Connect the pump to a power source using the main plug. 

The pump is ready for operation. 

 

 

Summary of Contents for PREMAxx

Page 1: ...application 1 5 Requirements of installation site 2 General Safety Notes 2 1 Notes concerning work safety 2 2 Explanation of safety note used 2 3 Risks when using the electrical pump PREMAxx 3 Assembly 4 Operation 4 1 First operation and renewed operation 4 2 Normal operation 4 3 Emergency operation 5 Disassembly 6 Maintenance 7 Repair Service 8 Declaration of EC conformity 87 987 A801 GB Version ...

Page 2: ... V AC single phase Type 2 24 V DC Type 3 12 V DC It is equipped with various nozzles with a standard nozzle or with a self closing automatic nozzle or with a self closing automatic nozzle with construction type approval according to 12 VbF tested by the PTB We happily supply the construction type approval on request The pump is delivered as a set comprising PREMAxx electrical pump in one of the ab...

Page 3: ... 24 V DC and 12 V DC 3 m Protection type IP 34 II Noise level 70 db A Table 1 2 General technical data 1 4 Area of application The PREMAxx electrical pump is only designed for pumping diesel and fuel oil if they are not heated above the flash point The temperature of the delivered fluid must be between 10 C and 35 C The temperature limits must not be exceeded As the motor and switches of the PREMA...

Page 4: ...instructions before operating the PREMAxx electrical pump and pass these on to any other users of the pump In any case the local safety and accident prevention provisions apply for the operation of the PREMAxx electrical pump Please pay attention to the safety notes in these operating instructions 2 2 Explanation of safety notes used The safety notes used in these operating instructions distinguis...

Page 5: ... with insufficient resistance can cause explosions In order to deliver the fuel without risk the delivery hose must have a certain resistance in order to avoid static charge The original delivery hose from FMT has the necessary resistance Use only FMT delivery hose When using delivery hoses by other manufacturers it must be ensured that the delivery hose has a resistance of 1011 Ohm Caution Leakin...

Page 6: ... lever 12 On off switch 3 Barrel screw joint 13 Pressure union 4 Suction union 14 Union nut of delivery hose 5 Hose clamp 15 Delivery hose 6 Suction hose 16 External thread of delivery hose 7 Hose clamp 17 Automatic nozzle 8 Suction pipe with filter 18 Lock lever 9 Standard nozzle 19 Trigger of automatic nozzle 10 Trigger of standard nozzle 20 Thread of automatic nozzle 6 ...

Page 7: ...r the fuel to be delivered without risk the delivery hose must have a certain resistance in order to avoid static charge The original delivery hose from FMT has the necessary resistance Use only FMT delivery hose When using delivery hoses by other manufacturers make sure that the delivery hose has a resistance of 1011 Ohm Caution Risk of product damage Mount and operate the pump only vertically on...

Page 8: ...ready to be switched on 4 2 Normal operation Danger Flying sparks can cause explosions Do not operate the pump in areas with a risk of explosion Use pump only to deliver diesel or fuel oil Caution Risk of product and environmental damage Regularly check delivery hose and connection for damage in order to avoid leakage of diesel or fuel oil Operate pump only under supervision Do not let the pump de...

Page 9: ...mp 12 2 Hold the nozzle 17 into the vehicle tank 3 Press up the nozzle trigger 19 according to the desired delivery quantity or lock the nozzle trigger using the lock lever 18 4 To end the delivery release the nozzle trigger 19 or briefly raise and release the locked nozzle trigger 19 to release the locking 5 Switch off the pump 12 6 Place the nozzle 17 on the fuel container 4 3 Emergency operatio...

Page 10: ...aintenance The PREMAxx electrical pump is in principle low maintenance and low service Due to the operator duty according to 191 WHG the following parts of the pump must be checked regularly to avoid environmental damage being caused by emerging fuel oil or diesel Pump housing 1 Delivery hose 15 Nozzle 9 or 17 In case of any damage the connecting cable has to be replaced or repaired by the manufac...

Page 11: ...tion becomes null and void Name of appliance PREMAxx 230 V AC single phase 24 V DC 12 V DC Appliance type electrical pump Year of construction see appliance sign Applicable EC guidelines EC low voltage guideline 73 23 EWG EC guideline of electro magnetic compatibility 89 336 EWG in the version of 93 31 EWG National standards applied DIN VDE 0843 Part 1 11 12 2009 FMT Swiss AG Dipl Ing Rudolf Schle...

Reviews: