background image

Installation Manual FMS winderGLIDE BKS.D.6

 

 

 

07.08.2017

 

 

5

 

 

 
 
 

Dimensions (see Fig. 1 and Fig. 2) 

in mm [in] 

Steering offset L 

125 [4.9] or 200 [7.9] 

Bracket distance A in center position of toggle link 
sockets 

236 [9.3] + L 

Total length B at full travel positions 

236 [9.3] + 2L 

Total length C 

266[10.5]  + L 

Power Supply Unit (l * w * h) 

227 * 125.2 * 100 

[8.9 * 4.9 * 3.9] 

Screw pitch 

 
 
 

2.2

 

Order Code (Example) winderGLIDE Type D.6 

 

 

     BKS.D.6. 

125 

 
Series 
Steering offset 
 
 

2.3

 

Scope of Delivery 

-

 

Actuator with spherical rod ends on both sides 

-

 

Supply Unit NTS-24A-10A 

-

 

Cable to Supply Unit 

 
Not included in the scope of delivery are the preassembled cable to the Electronics 
and alternative mounting devices. Additional mounting devices like clevis, hinge or 
flange for front mounting can be ordered separately. 

 

Summary of Contents for winderGLIDE BKS.D.6 Series

Page 1: ...or for unwind and rewind stations Document Version 1 20 08 2017 NS Diese Bedienungsanleitung ist auch in Deutsch erh ltlich Bitte kontaktieren Sie Ihren n chstgelegenen FMS Vertreter by FMS Force Meas...

Page 2: ...2 Order Code Example winderGLIDE Type D 6 5 2 3 Scope of Delivery 5 3 Installation 6 3 1 Assembly Conditions 6 3 2 Mounting the winderGLIDE Type D 6 6 3 3 BKS D 6 System Overview 8 3 4 Installation on...

Page 3: ...ction can be the result 1 2 List of Safety Instructions The main supply terminal on the Power Supply Unit can be under a tension of 95 264 VAC Mortal danger Only specially instructed and qualified per...

Page 4: ...Installation Manual FMS winderGLIDE BKS D 6 07 08 2017 4 2 Product Data 2 1 Mechanical Dimensions Fig 1 Outline Drawing Actuator BKS D 6 0001 Fig 2 Outline Drawing Power Supply Unit BKS D 6 0003...

Page 5: ...5 L Power Supply Unit l w h 227 125 2 100 8 9 4 9 3 9 Screw pitch 5 2 2 Order Code Example winderGLIDE Type D 6 BKS D 6 125 Series Steering offset 2 3 Scope of Delivery Actuator with spherical rod end...

Page 6: ...during assembly nor operation In particular it may not be operated outside the specified temperature range and protection class Caution The attachment points for the winderGLIDE on the machine must b...

Page 7: ...D 6 0002e The static part of the winderGLIDE must be mounted to the machine frame e g by means of the spherical rod end on the gearbox or the flange at the end of the spindle housing The moving rod e...

Page 8: ...nual FMS winderGLIDE BKS D 6 07 08 2017 8 3 3 BKS D 6 System Overview Fig 4 winderGLIDE BKS D 6 components and cabling BKS D 6 0009e 3 4 Installation on unwinding station Tension_Control_Web_Guiding_S...

Page 9: ...nderGLIDE BKS D 6 07 08 2017 9 3 5 Installation on winding station Tension_Control_Web_Guiding_Scheme_Schema ai 3 6 Connecting the Actuator widerGLIDE BKS D 6 Fig 5 Cable Terminals of the Power Supply...

Page 10: ...n after having properly connected the cables on the terminal Caution In operation the rated current in the BKS D 6 actuator can reach up to 10A In order to ensure an adequate conductor cross section i...

Page 11: ...table for the food and pharmaceutical packaging industry The backlash free 5mm pitch spindle ball screw systems are available in a choice of 125mm or 200mm lengths for greater positioning flexibility...

Page 12: ...echnology com FMS Italy Via Baranzate 67 I 20026 Novate Milanese Tel 39 02 39487035 Fax 39 02 39487035 fmsit fms technology com FMS USA Inc 2155 Stonington Ave Suite 119 Hoffman Estates IL 60169 USA T...

Reviews: