10.3
Hardware Specification
Funktion
Description
Number of Channels
1 channel for 2 force sensors
Sensor Supply
5 VDC, max. 30mA, high stability
Input Signal Range
0...9mV (max. 12.5mV)
Resolution of A/D-Converter
±2048 Digit (12 Bit)
Analogue Output
0…10V min. 1.2k
Ω
Resolution of D/A-Converter
0...4096 (12 Bit)
Measuring Error
<0.05% FS
Cycle for Data Exchange
≥
1ms
Interface Connectors
EMGZ 490.R: 2x RJ-45
EMGZ 490.W: 2x M12 4-pole D-coded
Parameter Setting
over PROFINET or web interface
Certification
PROFINET specification V2.1, CC-B
POFINET IO net load guide line Version 1.0, Nov. 2010; Order No. 7.302
Power Supply
24VDC (18...36VDC) / 5W
Temperature range
-10...60°C (14...140°F)
Weight
370 gr, [0.82 lbs]